Greetings fellow boatanchorites!
 

I need help from all the BA gurus out there practiced in the mysterious art
of grinding FT-243 type surplus crystals to operate in the ham bands.
 

I have had some success bringing crystals down in the 6.8 to 6.9 MHz range
up into the 40 meter band using dry "ultra fine" grade sandpaper. Some have
resulted in fine CW tones, others seem to be chirpy and have rather lousy
short term stability as the transmitter is keyed ( less than 1/2 second of
instability). I realize this instability is a characteristic sound of the
era, but some of these crystals seem to be overly unstable and are just
about unusable for CW work.

So, I'd like to call on the collective experience of all you OTs out there,
to help pass on this magical, little understood, and quite possibly lost art
of grinding surplus FT-243 type crystals into the ham bands. What were all
the tricks of the trade back then? Are there any new fangled products on
the market that would make this task easier or more accurate?

I also have some general questions on the subject:
Is there a limit in how far you can change the frequency of a crystal?
Seems my attempts at bringing crystals up from 6.7 MHz and below up into
the 7.0 MHz range have all resulted in very chirpy output signals.
 
I've heard that you can alter the frequency slightly up or down by
changing the spring tension inside the crystal. If so, does more tension
lower or increase the frequency?

What's the best trick to keep from overshooting your desired frequency?

Also, is there a frequency or section in the 40 meter band that is the hang
out for Vintage/Classic gear?

In case you're curious, I'm using these crystals in Johnson Viking Valiant,
WRL Globe Chief 90A and Allied Knight T60 transmitters.
 
Thanks in advance for any and all help!
73 from a young pup trying to get the old dogs to teach me some new tricks.
 
Paul, N6HCS

carreiro@netcom.com



From: "Hal R. Waite" 
Subject: Re: Help in FT-243 Grinding
 
Try tooth paste or better yet tooth powder in a heavy water slurry
on a glass plate. Using light pressure from the second finger (the
one that is used for signaling) and a circular motion, grind each of
the straight outer edges lightly. Then clean off and dry. If you
overshoot, a small amount of pencil lead rubbed on the center of the
crystal face will either lower the frequency or cause it to fail to
oscillate.

This takes a light touch and a bit of practice. Avoid grinding the
center of the crystal face.
 
Hal K4GFI/7 halwaite@netcom.com
 

 
From: "Roberta J. Barmore" 
Subject: Re: Help in FT-243 Grinding

Hi!
[Fair warning--most of what I'm going to say is hearsay, culled from
old magazines rather than actual experience. At least one fellow who
posts to the list has ground his own xtals from *scratch,* and I'm
hoping he'll have additional comment--oh, Gordon???]

On Fri, 4 Aug 1995, Paul Carreiro wrote:
> I have had some success bringing crystals down in the 6.8 to 6.9 MHz range
> up into the 40 meter band using dry "ultra fine" grade sandpaper. Some have
> resulted in fine CW tones, others seem to be chirpy. [...etc. ...]
 
Based on what I've read, any grade of sandpaper is too rough--scouring
power for big jumps, toothpaste for small ones & final grinding on the
larger changes. You can also get grinding paste in various grades at
hardware stores, though most of what I see is in a waxy base for
buffing-wheel work.
You've got to keep both of the large surfaces parallel and flat! Work
on a slab of plate glass (try junk shops, glass stores, and/or any
telescope hobbyists you know--don't take a used lens grinding glass,
though, it's not flat any more), and for small rocks, consider grinding a
bit of thick brass flat and using it to push on the crystal with. If it
goes inactive, grind gently at the corners.

Cleanliness is *vital.* before putting it back in the holder, wash your
hands, rinse the crystal; set it down on a *clean* and soft surface, wash
your hands again, put on gloves and clean it with something that'll zap
any oil, like 1,1,1 trichlorethane ("Carbo-clor") or possibly *denatured*
alcohol. (With older rocks, "cleaning the crystal" was a regular thing).
Wash your hands before you start, too, and don't touch your face or hair
while thinking what to do. (A dab of denatuared or trichlor will de-oil
your hands, though it doesn't do the skin any good [yessiree, that's why
I'm a hand model now, ha!] and may be hazardous--EPA and kin aren't very
keen about trichlor).

B
> I've heard that you can alter the frequency slightly up or down by
> changing the spring tension inside the crystal. If so, does more tension
> lower or increase the frequency?

More tension, higher freq--within limits! Saw mention of this and
other tricks, like adding a shunt trimmer condenser, in an old CQ just the
other day. (Naturally I can't find it now). The article mostly concerned
making 'em tweakable--the best trick was an FT-243 version of the old
vari-gap "rubber crystals," for which purpose it was suggested the best
type of tension spring was made of a retangular plate with a half-circle
bend in the center and the long sides bent flat with a 1/8" radius
half-circle cut-out in the center of the long sides (end view like an
omega, looking at the short sides; top view, a sort of fat H, wider than
it is tall). Drill and tap the cover plate in the center, run a screw
into the tapped hole, and you have a tweakable xtal. Tweak too far and it
may break; that's at your risk and no liability on the part of the writer
is implied or assumed. Offer void where prohibited. :)
 
> What's the best trick to keep from overshooting your desired frequency?

Go slow, check often. Most GDOs will work for xtal checking--tune it
in on your receiver to check freq. If you run up the meter sensitivity,
a good crystal will give a *lot* of deflection. A five-prong or octal
tube socket and some plugs that'll fit the coil jacks on the GDO make a
nice test fixture. (A five-prong socket can be wired to fit both
"doorknob" and FT-243 rocks, a trick I saw for the first time last week
and am now finding in a lot of places--tie pins 3 & 4 together, and use
pin two for the other connection).
If you like fiddlin' measurements, buy a cheap micrometer; measure the
thickness, check freq; grind a bit and check & measure again. By the
third iteration, you'll be able to plot a fair curve correlating
thickness and freq, which will hold pretty close for other crystals of
the same type and range. Still need to fire it up and *see* in the last
stages, especially if you're trying to hit a specific freq. (There are
ways to fake up a micrometer, with a well-calibrated dial and fine-theaded
hardware, a Depression-era trick; using a real mike is probably just as
cheap nowadays).
 
Hope that's of some use.
73,
Bobbi
 

 
From: "Ray L. Mote" 
Subject: Re: Xtal Grinding
 
1. Bon Ami powdered cleanser makes a good grinding paste. Been using
that for over 30 years now.
 
2. The plate glass out of the front of an *old* (BA-era) TV set makes a
good grinding surface. Just spread the paste on the glass and have at it
*very* gently with a circular motion.
 
3. ***N E V E R*** try to grind both sides of a crystal using this
technique! Put a bit of permanent ink or whatever on one side before
starting, to show you which side *not* to grind on each attempt.
(Translation: always grind the same side.)
 
4. Never tried grinding the edges. Will have to let those with
experience talk about it.
 
5. I've never had decent results more than 5-7 Kc away, if I remember
correctly. (Yeah, I've got Crumbling Mind Syndrome like a lot of other
folks.)
 
6. There were a number of articles written on this topic in QST, CQ, 73,
etc. If you can get next to a CD-ROM version of "From Beverages Through
Oscar", you might do a search on XTAL and grinding.
 

 
From: "nuusers" 
Date: Sat, 5 Aug 1995 21:56:37 EST
Subject: Re: Help in FT-243 Grinding
 
Back in 1969 I was interested in making a xtal filter for 455 Kc
(oh,oh, I mean 455 Khz) and an old timer showed me how to "edge
grind" old military xtals. The ones I used had a lead fused to the
each side of the thin material. It worked great...in fact an
other old timer gave me about 100 of the xtals...I think they worked
in the SCR-522 sets but there fundamental freq. was 400-500 Kc
range...to build him a I.F. filter...
 
On the presure type (FT453 I think) xtals, the secret is to take your
time...use 100, 200, 300, and 400 grit NON EMBEDDING grinding
compound (Clover brand). The only place I have ever seen it for sale
is machine tool and gun smith supplies. Do not use valve grinding
compound as it is an imbedding type!! You take it down fast with 100
then go to 200 and finish polish with 300 and 400. You use a flat
plate glass piece to grind on. Once you are finished you let the
xtal soak in for about a week in old developing solution that has
been used a lot...this silver plates it. Take the xtal out of
solution with cotton gloves so as not toget grease or rub off the
coating. Take a clean piece of plate glass and put white tooth paste
on the glass and rub the coating off the edges. There is also a
trick for measuring activity and frequency with a sig gen, vtvm and a
freq meter...but I can't remember off hand...good luck!!!
73,
Steve, KD1DT
 

 
From: wendler@tomcat.adc.ray.com (John Wendler)
Subject: Crystal Grinding
 
In re: Crystal Grinding...
Bobbi's summary looked pretty good, from what I remember reading.
I remember also seeing something about using Hydroflouric Acid
as an etchant, but would discourage anyone from pursuing this
option unless they are a trained chemist operating in a proper
lab with proper garb. HF is absorbed through the skin and goes
to the bone. All reports indicate that this is extremely painful.
 
I looked into crystals at one point from a professional perspective;
checked into the books and talked with some colleagues who make
the world's lowest phase noise SAW devices. Suffice to say that
cleanliness, proper processing, and good materials are all necessary
to go for "world class." For well made crystals, the differences in
performance between nitrogen atmosphere, ambient atmosphere, vacuum,
in a cold weld or resistance weld or a glass package are all very
noticeable. The presence of a gas will dampen the vibrations, decreasing
the Q. Contaminents will settle on a crystal, lowering the frequency
and the Q; this can be part of the aging characteristics or a
deliberate tuning strategy. Pencil lead, anyone? How about water
vapor from the atmosphere, and dust in the package?
 
You can guess where WWII crystals end up in the general scheme of things,
as well as crystals for microprocessors, etc that are cranked out by
the million. We are fortunate that we do not require world class for
amateur application!
 
One book had a calculation of the acceleration that an atom on the
surface of the crystal suffers... I seem to remember ~1,000,000 G.
Deflections were on the order of an atomic diameter, if the memory
hasn't completed faded this morning. I would certainly expect
the lead to move around over the long term, thus changing the frequency
slightly.
 
I hope this background gives a little insight into why tuning with
a pencil can sometimes cause problems, both long and short term, as
well as why some of the old style crystals might require periodic
cleaning as Bobbi mentioned.
 
A common cleaning process in many semiconductor fabs (for grease
removal) is (was? EPA?) some kind of Trichloro for grease removal,
followed by methanol for Trico removal, followed by de-ionized
water for methanol residue removal. The DI water is then baked
off. I used something similar to this while preparing samples
(electronic, not insectile) for a scanning electron microscope.
(There! I got mention of a hollow state device into this post,
so it's partially legitimized!)
 
You may want to consider distilled water from the supermarket
for the final clean up of your crystal. I know that I would not
use the water from my faucet to clean it; it's loaded with iron!
 
BTW, you may want to check your can of Tuner Cleaner/Degreaser
ingredients; my can will double for the Trichloro and alcohol steps
above, even though the ingredients are not exact.
 
73 es GL
John
 

 
From: "Roberta J. Barmore" 
Subject: Re: Xtal Grinding
 
Hi!
I'd like to expand on the following, for the benefit of the younger
folks. (It's just a good thing my rheumatiz' isn't actin' up, Sonny! )
 
On Sat, 5 Aug 1995, Ray L. Mote wrote:
> 3. ***N E V E R*** try to grind both sides of a crystal using this
> technique!
 
Occurs to me it's might not be clear *why* this is so--you see, if we
want our xtal to be a good one, both sides need to be *parallel* (if not,
you can end up with a dead'un--or worse) and remain at the original angle
to the crystalline structure of the quartz. In particular, the AT-cut is
a bit fussy; you can think of this common cut as a way to combine the
frequency vs. temperature characteristics of the ol' X and Y-cut rocks,
which are opposite in sign but of differing slopes. [Real Engineering and
Science types among us will know I'm glossing over a lot in that
assertion, but it covers the gross effects]. Get too far off, you've got
a drifty rock, and the poor feller with a super-solid-state-Whizbang
Wonder xcvr will *not* be able to follow you; he doesn't know from drift.
A hardware-store micrometer might be very useful for checking
parallelism, especially if you plan to do a lot of crystals. (At what
they're getting for 'em new, moving the surplus ones is pretty
attractive!)
There's also some things having to do with surface smoothness that come
into play, and saving at least one of the original surfaces helps keep the
rock active--might be wise to put the side you've been grinding against
the plate that's got a spring right back of it; last time I opened up a
junk FT-243-type holder, there was only a spring on one side. (Dunno if
they're all that way).
 
Oh, the flattish metal spring I mentioned in an earlier post can be
found in some types of mil-surplus crystal holders. (I found the
article). Interested parties can e-mail me for details & such. Think it
was the March '62 CQ.
 
A source tells me Petersen is looking to get back into crystals for ham
gear. Anyone know for sure? Can't seem to find their number....
 
73,
--Bobbi
 

 
From: swheaton@www.tyrell.net (Sheldon Wheaton)
Subject: Re: Help in FT-243 Grinding
 
I've ground quite a few xtals for my use in the Antique Wireless
Association's annual CW QSO contests (Rig is 1939 vintage reproduction
6L6-809). A couple of my comments on the subject:
 
For a given type of "cut" (direction of XTAL lattice molecular alignment),
the fundamental frequency is inversely proportional to the thickness. Most
FT-243 xtals are "AT" cut. The formula is listed in many early (1930's) ARRL
handbooks. Using this formula, and a good micrometer, you can make some
rough cuts without having to assemble the crystal every time.
 
Keep your eye out for old xtal grinding kits at hamfests. I have some with
different "grits" of grinding powder. Not sure what it is, but looks & feels
about like talcum powder, except gray in color.
 
If the xtal is not ground with both sides parrallel, you may end up with two
or more different "fundamental" frequencies! Not good.
 
Sometimes an otherwise good xtal that worked fine, but won't oscillate or
does so erratically after the last grind that moved it only 5 kc or so, can
be made to work correctly by slightly "beveling" all four edges on both
sides (8 edges total). This procedure is documented in many books of the
30's. It usually doesn't need to be a visible bevel, just a few "strokes"
with the compound.
 
I have best luck with a figure 8 motion for grinding. Some grinding kits
have a flat piece with a pentagon shaped, shallow cut-out, with inwardly
curved edges, which will make the quartz piece move around in an impressive
"Spiro-graph" type motion, but I haven't had much luck with this item.
 
gud luck & 73,
Sheldon KC0CW
swheaton@tyrell.net


 
From: morgan@speckle.ncsl.nist.gov (Roy Morgan, K1LKY)
Subject: Re: Help in FT-243 Grinding
 
>Greetings fellow boatanchorites!
>
>I need help from all the BA gurus out there practiced in the mysterious art
>of grinding FT-243 type surplus crystals to operate in the ham bands.
 
Here are some short notes on your questions:
 
-use wet finest possible wet-dry emery paper, or fine carborundum or even
toothpaste on a piece of glass.
 
-activity goes up and down as you grind the frequency upwards. You may have
just gotten to a poor spot on most of your crystals because of the distance
you moved the frequency.
 
-activity at/near a frequency depends on thickness/width ratio so activity
can sometimes be restored by grinding the edge(s) of the crystal. Frequency
will likely got up as you grind the edge. Do a LITTLE at at time.
 
-a crystal in a holder with some dust will act strange, if it oscillates at
all, so be CLEAN when assembling. Handy things to have are: acetone or
alchohol, clean - the kind you might get at the paint store may not be too
clean (and ventilation!), little soft brush from the art store, blower like
a bulb-type solder sucker or baby nose syringe ...
 
-increasing spring pressure in the holder will usually increase frequency, I
think. beware of cracking the thing.
 
-a bit of pencil lead or solder rubbed on the flat surface will lower the
frequency by making it heavier, and doing this may help you predict what
will happen if you grind the edges.
 
-capacitance of the oscillator circuit may affect the activity of a crytal
you've ground.
 
I'm intersted in making up a "standard" oscillator circuit - I have a
handbook giving lots of tube circuits. I'd be glad to cooperate on this
project if you'd like.
 
-- Roy --
Roy Morgan / Tech A-266 / NIST / Gaithersburg MD 20899
(National Institute of Standards and Technology, formerly NBS)
301-975-3254 Fax: 301-948-6213 Internet: morgan@speckle.ncsl.nist.gov


 
From: Andy Wallace 
Subject: xtal grinding monitor -- someone TRY THIS.
 
Also in the '49 Hints and Kinks book is a method (page 88) of
monitoring the frequency of a quartz crystal DURING GRINDING.
 
Take a flat piece of aluminum or copper about 6" square, and connect
it to your receiver antenna post using a short lead. Place the plate
glass on which the grinding is being done on this sheet. You
can tune in the crystal frequency on the receiver by the scratches you hear
as the crystal is being ground.
 
This is the first time I've ever heard of something like this, but
I assume the laws of physics and piezoelectricity allow this to
work. 'scuse me, I have to go take apart a picture frame and find
some PC board material! But seriously, would someone on the List
volunteer to try this? Fascinating...
 
--Andy
wallace@mc.com
 
P.S. The H+K book also recommends automotive valve grinding compound for
speedy xtal grinding. Hmm...I smell some new Novice xtals coming on,
maybe even for 80m.


Please Email to add YOUR additional comments to this web page


Web Counter
You are visitor number: since 2 September, 1996

((From our friends at: www.digits.com))


E-mail me


top BACK TO THE TOP

back

Back to: THE CRYSTAL PAGE



CLICK HERE TO go to the ham LINKS DIRECTORY!


You are visiting the website at: http://home.earthlink.net/~af4k/
Come back soon!