Bactericidal/Asepticizing device
"Suijin", "Shiden", "Huujin"
Nobody can be indifferent to the quality
of domestic water or possible microbial contamination
of supplied water from its upstream sources,
tap water or private well, that has been
a cause of widespread infectious diseases
over years.The contamination is hardly noticed
visibly but affects our life seriously.@
Bottled water may be bought for limited domestic
uses. A kind of solution. But do you wash
all of foodstuffs, dishes and kitchenware
with bottles of water?
How about for bathing or washing clothes?
You have to eat up stupendous amount of budget
for utilities cost.
A traditional way of sterilizing water is
boiling.
A large number of bacteria can be destroyed
by boiling, but thermoduric bacteria still
survive.
The boiled water cannot be used immediately
and cooldown time is required.
There is no way or means of avoiding microbe
infection during or after the cooling.
Our attention was drawn to the germicidal
effects of the ray of light.@The light employed
in our devices has germicidal capacity of
1600 times of the sunlight and by directly
destroying DNA, it eradicates microbes in
a short period of time.
Any kind of microbes, germs, yeast or fungus
is completely eradicated by this method.
Different from the sterilization by chemicals,
this method will derive no resistant bacteria.
It requires no secondary treatment or neutralization
processes like the case of chlorine sterilization,
nor cooldown time that may give rise to the
possibility of re-infection.
Operation does not require delicate control
nor combustible. Only small power sufficient
for lighting the lamp is enough.
Now, you have an effective and simple means
to improve the hygienic condition around.
If you bother yourself about freshness and
cleanliness of foods, fungal growth, preservation
of hygienic condition at your foods producing
facilities, sterilization of drinking water
for your livestock, antiseptic treatment
of draining water, etc., as well as the precaution
and protection of your family from the infectious
diseases, here's a good solution to select.
"Suijin", Faucet-applied
Bactericidal Device
Specifications :
Service voltage : 220 volts A.C. ( Indonesian Standards
)
Power consumption : 15 watts or less
Material : Water conducting tube :stainless steel
Chassis : PVC
Capacity : 400 litres per hour
Life of lamp : 3,000 hours( manufacturer's recommendation
4,000 hours)
e.g. treating 1,200 litres per day.(3 hours'
service)available for 1,000 days
Interval of lamp change : 3,000 hours
Dimensions : height 400 mm, width 180 mm, depth 70
mm,
Installation : wall-mounting
Application :
- Asepticizing tap water or well waterr for
kitchen, bathroom, etc.
- Hygienic treatment of water for cookking
in restaurant, etc.
- Hygienic treatment of water in barbeer shop,
beauty parlor, etc.
- Asepticizing water for aquarium, driinking
water for livestock, etc
- Production of aseptic water used forr services
in hospital(e.g. washing of medical apparatus)
@Please also refer to Bactericidal Device
for Airborne Microbes "Hujin."
Producing drinking water(Applied in combination
with optional water filters)
"Shiden", Tank/Reservoir-applied
Bactericidal Device
Specifications :
Service voltage : 220 volts A.C. ( Indonesian Standards
)
Power consumption : 20 watts or less
Material : Water conducting tube : stainless steel
Chassis : PVC
Capacity : eradicating coli bacteria in one minutes
irradiated from the distance of 500 mm.
Life of lamp : 3,000 hours ( manufacturer's recommendation
4,000 hours)
Interval of lamp change : 3,000 hours
Dimensions : length 750 mm, diameter 50 mm
Installation : hanging
Application :
- Asepticizing reservoir tank or cisteern
and stored water, etc.
- Asepticizing water tank and stored wwater,
etc.
- Asepticizing water sold in bottle(gaallon
size)
- Asepticizing water for aquarium, driinking
water for livestock, etc
Sterilization of bath tub, water closet,
refrigerator or similar narrow space
"Huujin" Superficial and
Atmospheric Bactericidal Device
Specifications :
Service voltage : 220 volts A.C. ( Indonesian Standards
)
Power consumption : 20 watts or less
Material : Reflector : stainless steel Chassis : PVC
Capacity : space up to 20 cubic metre
Life of lamp : 3,000 hours ( manufacturer's recommendation
4,000 hours)
Interval of lamp change : 3,000 hours
Dimensions : height 400 mm, width 180 mm, depth 70
mm
Installation : wall-mounted
Application :
- Asepticizing bathroom, water closet,, or
other sunshine-less room
- Prevention of fungal growth in warehhouse
or any compartment
- Asepticizing restaurant, kitchen or places
handling foods
- Asepticizing and deodorizing displayy cases
of meats or fishes
- Maintenance of clean or aseptic roomm in
laboratory, factory,etc.
- Asepticizing hospital, patient's rooom,
operating room,etc.
- Asepticizing places where raw foodsttuffs,
are handled
Caution:
1) Avoid direct sight of the germicidal light.
It may cause inflammation of eyes.When you
need to observe the light of lamp, do not
forget using protection sunglass.
2)Remind that long time radiation onto skin
may cause inflammation. Person who has delicate
skin shall take special precaution. Also,
pay much attention to children so that they
are not exposed to the radiation. In case
exposure is inevitable, applying UV Block
oil to your skin is recommended. Also remind
that plants will be stand decayed when exposed
to long time radiation.
Send E-Mail
CV J-tech Intelligence International
Margahayu Raya Barat Blok S2 No,71
Tel:022-756-0279
Mail:masairo-aizawa@col.hi-ho.ne.jp