CHAPTER 9: TROUBLESHOOTING CHART


Symptom

Cause

Resolve

20 dB drop Shorted CC Replace bad fitting
Abnormal RF attenuation Feeder suck out Set up MR
Beats on HFC Freq Bad RFI shielding Replace passive device
Black center conductor Water in cable Replace damaged cable
Blurry pic on trapped chs Increase in rejection bandwidth Replace trap
Chs 2, 11, 22 good,, all others have static IF RCA TV, TV problem Unplug TV for 30 secs and replug
Continuous Dialtone after dialing Reverse wiring between tip and ring Rewire to proper configuration
Crosstalk Use of non TPW
Poorly installed jacks
Corroded wires/connectors

Another service (SBC, etc) spliced into system
Set up for Install
Replace jacks
Replace wire/connectors
Disconnect other service from system
Dead DCT No power to DCT
DCT too hot
DCT is bad
Plug in DCT
Move DCT to allow air
Change out DCT
Error code Faulty DCT Check code and follow
Flashing Loose fittings
Broken shielding on drop
Damaged drip loop on mid-span
Shorted/ too long CC
Defective passive devices
Feeder/trunk issue
Tighten fittings
Replace drop

Replace drop
Replace fitting
Replace device
Set up MR
Flashing pictures
(sometimes)
Cross threaded fitting
Corroded/loose fitting
Loose seizure screw
Feeder suck out
Refit fitting
Replace fitting
Set up MR
Set up MR
Flashing/off receive light Downstream issue Level check downstream
Flashing/off send light Upstream issue Return path check
Fluctuating RF levels Cross threaded fitting Refit fitting
Frequency hopping Distortion for cascaded return amp
Legal /illegal over the air service
Amateur/CB radios
Impulse noise
Lightning
Set up MR

Set up MR

Inform customer
Set up MR
Inform customer
Frozen DCT screen Faulty DCT Replace DCT
Frozen navigation DCT fault Unplug DCT for 15-20 sec Plug it back in Request reauthorization
Herringbone beat Notch freq drift Replace trap
High ground resistance Broken bond wire
Drop not common bonded
Corroded ground contacts
High soil Resistivity
Loose grd screw
Undersized ground wire
Replace bonding wire
Common bond drop
Reconnect to good contact

Tighten screws
Replace with proper wire
High uncorrected errors Ingress on line Replace drop
High/no Return path Defective/wrong house amp
Loose fitting
Push on fitting
59 cable
Poorly installed fitting
Too many sets on line
VCR before DCT
Wire damage
Replace with correct amp

Tighten all fittings
Replace fittings
Replace cable if able to
Replace fitting

Add amp or reconfigure
Reconfigure set up
Replace wire if able
Hum bars Ingress Cracked housing
Hum modulation Defective DCT
Faulty RF switch
Defective DC power supply in amp
Low AC input voltage to amps DC power supply
Corroded power passing device
Defective house amp
Poor grounding
Defective CPE
Swap out DCT
Replace switch
Set up MR

Set up MR

Replace power passing device
Swap amp or AC adapter
Ground properly
Inform customer
Hum on phone line Ground/shielding on wire
Poor termination
Poor grd/bonding
Replace wire if able

Check connection
Replace suspect items
Impedance mismatch Cut/chewed cable
Stapled cable
Too tight fitting
Replace the damaged cable
Replace the damaged cable
Replace fitting
Ingress/ Ghosting Loose/corroded fitting
Badly installed fitting
Bad CPE
Moisture in cable
Severed cable
Violation of bend radius
Water in cable
Shorted CC
Wrong size fitting
Defective drop
Poor RFI shielding
Loose amp housing bolt
Faulty trap
Dielectric on CC
Cross threaded fitting
Cracked tap port
Cracked feeder
Push on jumper
Replace fitting
Replace fitting
Inform customer
Replace stapled cable
Replace severed cable
Replace bended cable

Replace damaged cable
Replace bad fitting
Replace bad fitting
Replace the drop
Replace passive device
Tighten or set up MR
Replace trap
Replace bad fitting
Refit fitting
Replace tap plate
Set up MR
Replace jumper
Inverted signal level Corroded fitting/grd block Replace fitting/grd block
Inverted tap levels
Water in the tap
Replace tap and set up MR
Level fluctuation Loose seizure screw Set Up MR
Loss of AC power Feeder suck out Set up MR
Low SNR in upstream Ingress on line Sweep line for ingress
Modem failing/freezing Ingress on line Sweep line for ingress
No chs over 13 CLI trap for leak
TV set up off cable

Power outage
Sweep for ingress
Reconfigure set up to cable
Reprogram TV chs
No dial tone CPE off hook

Short,open,grd fault
Dead cordless batteries
Place phone back on hook
Find fault in line
Replace batteries

No picture on all channels No signal to CPE

Corroded fitting
Cut cable
High RF levels
Check all connections at CPE
Replace fitting
Replace cut cable
Terminated unused port
No Sound on all channels Mute button on Depress mute button
No Sound on all channels Audio cords unconnected Reconnect audio cords
Noise on line MTA too close to item
Corroded fitting
Poorly installed fitting/jack
Move MTA

Replace fitting
Replace fitting/jack

One channel has noise Loose connection at CPE Tighten all connections
Opens in IW Corroded/damaged IW
Terminated Tip and ring to wrong screw
Loose connections at screws
Replace wiring if able
Wire to proper screws

Tighten all screws

Partial viewing of trap chs Notch freq drift Replace trap
Paste/powder on braid Water in cable Replace damaged cable
Poor audio on lower adjacent channel Notch freq drift downward Replace trap
Ringer issues No ring Ringer switch in "off" or "low" position
Defective CPE
Improper polarity of tip and ring
Excessive REN number
Ringer problem Reversed wiring
Ground Fault
Too many CPEs on line
Rewire connection
Find fault in line
Reduce number of CPEs if able
Ringer issues No ring Ringer switch in "off" or "low" position
Defective CPE
Improper polarity of tip and ring
Excessive REN number
Ringer problem Reversed wiring
Ground Fault
Too many CPEs on line
Rewire connection
Find fault in line
Reduce # of CPEs if able
Signal level < 10dB low Backward splice tap Set up MR
Slow modem speeds Ingress on line
Excessive network traffic
Computer speed
Low RAM memory
Sweep line for ingress
Speed test

Virus scan/speed test
Add memory (virtual)
Smearing Violation of bend radius Replace bended cable
Snowy pic on 23 and up Fitting/Grd block corrosion Replace suspect item
Snowy pic on 2-6, 14-22 Loose seizure screw
Feeder suck out
Set Up MR
Set up MR
Snowy Picture on all Low levels or no signal






Decrease in RF signal
Cut cable
Dielectric on CC
Lightning damage
Bad barrel at grd block
Defective trap
Low RF signal
At splitter check:

Wrong port connection
High insertion loss
Bad/corroded fitting
Wrong splitter type
Poor RFI shielding
Loose fitting
Replace damaged cable
Replace cut cable
Replace bad fitting
Replace grd block/splitter
Replace grd block
Replace trap
Replace broken port
Sound when DCT off RF bypass is setup Undo RF bypass setup
Static on phone line Loose/corroded fitting
Poorly installed jacks
Broken wires
Defective CPE
Refit fitting
Refit jacks
Replace wire if able
Inform customer
Suck out (meter roll off) Water in system
Water in tap

Set up MR
Swap out tap and set up MR
Tiling Low or high signal
Too many TVs
Cut in the drop
Ingress

Tighten loose fitting
Add house amp
Replace the drop
Find cause of ingress and repair