STATUS CODE |
DESCRIPTION |
BLANK |
No input voltage to card and/or display |
-01 |
No seat/deadman switch input |
-02 |
Forward directional switch closed on initial power up |
-03 |
Reverse directional switch is closed on initial power up |
-04 |
Start switch input low after initial start up |
-05 |
Start switch or brake switch fails to close |
-06 |
Accelerator depressed with no direction selected |
-07 |
Accelerator input voltage too high |
-08 |
Accelerator input voltage too low after key switch closure |
-09 |
Both FWD and REV directional switches closed at same time |
-11 |
Start switch closed on power up after key switch closure
(ZX series logic cards only) |
-15 |
Battery voltage too low |
-16 |
Battery voltage too high |
-17 |
Invalid/incorrect card selection type (Function 17) |
-21 |
Accelerator input less than .25 volts
(ZX series logic cards only) |
|
CONTACTOR PANEL |
-23 |
Forward and reverse contactor coil current low |
-24 |
|
-25 |
1A contactor does not drop out or drops out slowly |
-26 |
Shorted coil driver for SP or FW contactor |
|
SCR PANEL |
-41 |
Open thermal protector (TP) or control over temperature |
-42 |
Control motor current sensor input missing
(YELLOW/GREEN WIRE) |
-43 |
Control motor current sensor input missing
(GREEN/YELLOW WIRE) |
-44 |
1REC/SCR did not turn OFF properly |
-45 |
1REC/SCR did not turn ON properly |
-46 |
Look ahead test for T2 volts too high
(Greater than 85% of battery voltage) |
-47 |
2REC/SCR does not turn on properly |
-48 |
Look ahead test for T2 volts too low
(Less that 12% of battery voltage) |
-49 |
5REC/SCR did not turn on properly |
-50 |
1C capacitor voltage too low |
-51 |
Excessive capacitor voltage when motor current is HIGH |
-52 |
Excessive capacitor voltage when motor current is LOW |
-53 |
1REC/SCR fails to turn off during a plugging cycle |
-54 |
Shorted FWD, REV or 1A contactor coil driver |
-57 |
Current sensor input voltage polarity incorrect |
|
REGENERATIVE BRAKING |
-70 |
Regen current sensor input missing
(YELLOW WIRE) |
-71 |
Regen current sensor input missing
(GREEN WIRE) |
-72 |
Regenerative Braking contactor does not pick up |
-73 |
Regenerative Braking contactor does not drop out or drops out slowly |
-74 |
Regenerative Braking contactor picks up too slow |
-75 |
1REC/SCR fails to turn off during Regenerative Braking |
-76 |
1C capacitor overvoltage during Regenerative Braking |
-90 to -95 |
Truck Management Module (TMM) failures set up by OEM |
-90 |
Typically a failure at pin 1 of the TMM card |
-91 |
Typically a failure at pin 3 of the TMM card |
-92 |
Typically a failure at pin 4 of the TMM card |
-93 |
Typically a failure at pins 5 and 6 of the TMM card
(Check also that Handset adjustment knob is full counter clock wise) |
-94 |
Typically a failure at pins 8 and 10 of the TMM card |
-95 |
Typically a failure at pins 11 and 12 of the TMM card |
-99 |
Vehicle maintenence alert code
(ZX series only) |
|
SCR PUMP CONTROL |
-117 |
Invalid/incorrect card selection type (Function 17) |
-123 |
Pump or 1A contactor coil current low |
-124 |
T2 voltage low (less than 12% of battery voltage) |
1A contactor does not drop out or drops out slowly |
|
-141 |
Open thermal protector (TP) or control over temperature |
-142 |
Control motor current sensor input missing
(YELLOW/GREEN WIRE) |
-143 |
Control motor current sensor input missing
(GREEN/YELLOW WIRE) |
-144 |
1REC/SCR did not turn OFF properly |
-145 |
1REC/SCR did not turn ON properly |
-146 |
Look ahead test for T2 volts too high
(Greater than 85% of battery voltage) |
-147 |
2REC/SCR does not turn on properly |
-148 |
Look ahead test for T2 volts too low
(Less that 12% of battery voltage) |
-149 |
5REC/SCR did not turn on properly |
-150 |
1C capacitor voltage too low |
-151 |
Excessive capacitor voltage when motor current is HIGH |
-152 |
Excessive capacitor voltage when motor current is LOW |
-154 |
Shorted pump or 1A contactor coil driver |
-157 |
Current sensor input voltage polarity incorrect |