TYPE OUTPUT (MW) VOL. M3 MASS
COST FULE Kl/hr MCr Fule/hr
IICE TL6 0.004 0.01 0.01
0.00002 0.001 0.0000002
IICE TL6 0.01 0.025 0.025
0.00005 0.0025 0.000000625
IICE TL6 0.1 0.25 0.25 0.0005
0.025 0.00000625
IICE TL6 0.4 1.0 1.0 0.002
0.1 0.000025
IICE TL6 0.5 1.25 1.25 0.0025
0.125 0.0000321
IICE TL6 0.75 1.875 1.875
0.00375 0.1875 0.0000468
IICE TL6 0.8 2 2 0.004 0.2
0.00005
IICE TL6 1 2.5 2.5 0.005 0.25
0.0000625
IICE TL6 1.5 3.75 3.75 0.0075
0.375 0.0000936
IICE TL6 2 5 5 0.1 0.5
0.000125
IICE TL6 4 10 10 0.02 1
0.00025
IICE TL6 5 12.5 12.5 0.025
1.25 0.000312
IICE TL6 10 25 25 0.05 2.25
0.000625
Gas Turbine TL7 0.25 0.5 0.5
0.0025 0.0075 0.0000187
Gas Turbine TL7 0.5 1 1 0.005
0.15 0.0000375
Gas Turbine TL7 1 2 2 0.01
0.3 0.000075
Gas Turbine TL7 2 4 4 0.02
0.6 0.00015
Gas Turbine TL7 4 8 8 0.04
1.2 0.0003
Gas Turbine TL7 5 10 10 0.05
1.5 0.000375
Gas Turbine TL7 10 20 20 0.1
3.0 0.00075
Gas Turbine TL7 20 40 40 0.2
6.0 0.0015
Gas Turbine TL7 50 100 100
0.5 15 0.00375
Gas Turbine TL7 100 200 200
1.0 30 0.0075
Steam Turb TL5 0.35 1 2 0.002
0.0525 0.0000131
Steam Turb TL5 0.7 2 4 0.004
0.105 0.0000262
Steam Turb TL5 1.0 2.86 5.72
0.00572 0.15 0.0000375
Steam Turb TL5 2.0 5.72 11.44
0.01144 0.3 0.000075
Steam Turb TL5 10 28.6 57.2
0.0572 1.5 0.000375
Steam Turb TL5 50 143 286
0.286 7.5 0.001875
Steam Turb TL5 60 171.5 343
0.343 9 0.00225
Steam Turb TL5 100 286 572
0.572 15 0.00375
Steam Turb TL5 600 1715 3430
3.43 90 0.0225
Steam Turb TL5 1000 2860 5720
5.72 150 0.0375
Nuc. TL7 57t 12 20 160 2.0
3Kl/yr 4.275MCr/yr
Nuc. TL7 285t 60 100 800 10
15Kl/yr 21.375MCr/yr
Nuc. TL7 2850t 600 1000 8000
100 150Kl/yr 213.75MCr/yr
NOTES:
IICE TL6: Tech Level 6
Inproved Internal Combustion Engine powered by hydrocarbon
distillates
Gas Turbine TL7: Tech Level 7
Gas Turbine powered by hydrocarbon distillates
Steam Turb TL5: Tech Level 5
Steam Turbine powered by hydrocarbon distillates
Nuc. TL7 57t: Tech Level 7
Nuclear Fission Power Plant - consumes 57 tonnes of radioactives fule
per year
OUTPUT (MW): The power output
of the particular engine in MW
VOL M3: The volume of the
powerplant in cubic metres
COST: The cost of the
powerplant in MCr
FULE kl/hr: Fule consumption
of the powerplant in kiloliters of fule per hour
MCr Fule/hr: Cost of fuel for
a particular powerplant on a per hour basis - very usefule if ypu
want running costs!
DISCUSSION OF SERKUR
POWERPLANTS
The above is a selection of
standard powerplants used on the planet Serker. The smaller ones may
be used to power certain vheicals; the larger powerplants may be used
to pump electricity in to the national (planetry!) grid. This table
was produced with the intention of having a selection of
pre-generated powerplants that could be plugged into any vheical
designed for this planet. It is my intention in future to also put
together similar tables of standard hulls for AFV's etc and weapons,
wich should greatly speed up any future vheical designs.
DISCUSSION ON ELECTRICITY
GENERATION
An interestin eccersise was
to compare the relative generation costs for some of the powerplants
to see if they were reasonable.
TL5 Steam Turbine
600MW
Running cost/year = 197.1MCr
(thats 788400kl/year, 2365200tonnes HCD per year)
(assumes 8760hrs/standard
year)
Cost to build:
3.43MCr
TL7 Nuclar 600MW
Running cost/year = 213.75MCr
(see table above)
Cost to build: 100
MCr
Nuclear powerplants are more
expensive to build and run!
Lets take the worst case
scenario - a nuclear plant costing 100MCr to build and 231.75MCr/year
to run.
Running costs alone are
0.0000406MCr/ MegawattHoure (0.0406Cr/KWhr or 4.06cents per kWhr (are
there 100 cents to the credit?!)
Adding in the cost of
building the plant averaged over 20years life expectancy plus
interest and other running and maintanence costs (eg: wages) one
would expect a generation cost of about 10c per kWhr which is about
what we pay today!