Step |
Condition |
Adjustment |
Procedure |
1 |
MODE:
RX AM
Ch. 19 MID. |
L17 |
Connect
oscilloscope on TP4. Adjust for maximum reading. |
2 |
MODE:
RX AM
Ch. 40 MID. |
L18 |
Connect
DC Voltmeter on TP2. Adjust to obtain 5,5Volt. |
3 |
MODE:
RX AM
Ch. 19 MID. |
L19 |
Connect
oscilloscope on TP3. Adjust for maximum reading. |
4 |
MODE:
RX AM
Ch. 19 MID. |
L25 |
Connect
Frequency Counter on TP3. Adjust to obtain 16.490MHz +/-
20Hz. |
5 |
MODE:
RX USB
Ch. 19 MID. |
L26 |
Connect
Frequency Counter on TP3. Adjust to obtain 16.4925MHz +/-
20Hz. |
6 |
MODE:
RX LSB
Ch. 19 MID. |
L27 |
Connect
Frequency Counter on TP3. Adjust to obtain 16.4875MHz +/-
20Hz. |
7 |
MODE:
TX LSB
Ch. 19 MID. |
VR6 |
Connect
Frequency Counter on TP3. Adjust to obtain 16.875MHz +/-
20Hz. |
8 |
MODE:
RX AM
Ch. 19 MID. |
L22 |
Connect
Frequency Counter on TP3. Adjust to obtain 16.040MHz +/-
20Hz. |
9 |
MODE:
RX USB
Ch. 19 MID. |
L23 |
Connect
Frequency Counter on TP3. Adjust to obtain 16.0425MHz +/-
20Hz. |
10 |
MODE:
RX LSB
Ch. 19 MID. |
L24 |
Connect
Frequency Counter on TP3. Adjust to obtain 16.0375MHz +/-
20Hz. |
11 |
MODE:
RX LSB |
L30 |
Connect
Frequency Counter on TP6. Adjust to obtain 16.6975MHz +/-
20Hz. |
12 |
MODE:
RX USB |
L29 |
Connect
Frequency Counter on TP6. Adjust to obtain 16.6925MHz +/-
20Hz. |
13 |
MODE:
TX AM |
L28 |
Connect
Frequency Counter on Base from TR43. Adjust to obtain 16.6950MHz