Item 11. Total number of face conductors, Z
Subject for correction, use Z = (p Dq) / Ic
Subject for correction, when the number of slots, S is finalized.
Item 12. Number of Slots, S
Subject for correction: S = Z / Cs
Limited to the circumference of the armature, 2p r
Should be a whole number.
Item 13. Number of Conductor per slots, Cs
None, usually assumed.
Subject to the space within the slot width.
Usually, 4.
Slots per pole, S/p
Use: S/p.
Should be an integer plus 1/2.
Slots per pair of pole, S/p/2
Use: S/(p/2)
Should be an odd integer so that the Slots per pole is feasible.
Slots per pole arc [integer], S x r
Use Slot per pole x r
Should be an integer
Item 14. Axial length of armature core, gross, la
Determined from the final value of the output factor,
laD².
Subject for correction if flux density at item 15 is desirable.
Item 15. Flux per pole (open circuit), F
With final Z, use: F = (V x hz x 6 x 108) ¸ (p x N x Z)
Item 16. Pole Pitch, t
With final D, use: p D / p
Item 17. Pole arc, r t
With final t
This will result to final value of la ¸ (t r)
Item 18. Area covered by pole face, sq. in, la t r
Use: la t r
Compare result of B"g of item no.4 with standard.