Pablo Gómez Zamorano, Ph.D.
Professor
Instituto Politécnico Nacional, México
Currently as a posdoctoral fellow at  Polytechnic Institute of NYU, New York City
                         Spanish Version

                

 

 

 

 

 

Contacto

pgomezz@ipn.mx

pgomez@poly.edu

  

 
Ph.D. in Electrical Engineering, 2005
Centro de Investigación y de Estudios Avanzados del IPN Guadalajara, Jalisco, México

Research topic: Electromagnetic transients in Power Systems.

Thesis: Non Uniform Transmission Line Modeling for Electromagnetic Transient Analysis.

 

 

 

 

 

 

 

 

 
M.Sc. in Electrical Engineering, 2002
Centro de Investigación y de Estudios Avanzados del IPN Guadalajara, Jalisco, México
Research topic: Electromagnetic transients in Power Systems
Thesis: Modeling of Non-linear Conditions for Electromagnetic Transient Analysis Using the Numerical Laplace Transform.

 

 

 

 

 

 
Research
Major Topic: Modeling and Simulation for Electromagnetic Transient Analysis

° Modeling of Distributed Parameter Elements

° Modeling of Non-linear and Frequency Dependent Behavior
° Analysis of Switching and Lightning Induced Transients
° Developments in Time and Frequency Domain Numerical 
° Applications of EMTP-type Programs
Other Research interests:
° Electromagnetic Compatibility
° Insulation Systems
° Network Analysis and Synthesis
° Harmonic Interaction
° Digital Protection

Mechanical and Electrical Engineer, 1999
Universidad Autónoma de Coahuila                                    Monclova, Coahuila, México
Major: Electricity and Electronics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Thesis Supervising
M.Sc. Students

° Maria del Pilar Arellano Recillas, “Evaluation of Switching Overvoltages Related to the Restoration of Transmission Systems Using a Frequency Domain Method”, SEPI-ESIME-IPN. June 2006.

° Jahel Hernández Ángeles, “Implementation of Arc Models for the Simulation of HV Breakers using EMTP”, SEPI-ESIME-IPN. December 2006.
° Juan Carlos Escamilla Sánchez, "Analysis of the transference of transient overvoltages induced by direct and indirect lightning in distribution networks", SEPI-ESIME-IPN. June 2008.
° Carlos Tejada Martínez, “Analysis of Radio Interference related to Corona in HV Transmission Lines”, SEPI-ESIME-IPN. June 2008.
° José A. de León Brito, “Analysis of the Effect of PWM-type voltages in the insulation systems of medium voltage components fed by adjustable speed drives”, in progress.
Undergraduate Students
° Tomás Flores Portillo and Carlos Tejada Martínez, “Analysis of Overvoltages due to Switching Transients in Transmission Systems”, ESIME-IPN. June 2006.

 

 

 

 

 

 

 
Publications
Journal

 °    P. Gómez, P. Moreno, J. L. Naredo, “Frequency Domain Transient Analysis of Non-Uniform Lines with Incident Field Excitation”, IEEE Trans. Power Delivery., vol. 20, no. 3, pp. 2273-2280, July 2005.

° P. Moreno, P. Gómez, J. L. Naredo, J. L. Guardado, “Frequency Domain Transient  Analysis of Electrical Networks Including Non-linear Conditions”, ELSEVIER Int. Journal of Electrical Power & Energy Systems, vol. 27, Issue 2., pp. 139-146, February 2005.
°  P. Gómez, F. A. Uribe, “On the Application of the Numerical Laplace Transform for Accurate Electromagnetic Transient Analysis”, Rev. Mex. Fis., vol. 53, no. 3, pp. 198-204, June 2007. [PDF]
 ° P. Gómez, P. Moreno, “Simplified Method of Characteristics for Fast Transient Solution  of Frequency and Space Dependent Transmission Lines”, Rev. Científica, vol. 11, no. 4, pp. 159-167, October 2007 [PDF]
° J.C. Escamilla, P. Gómez, C. Tejada, “Single-phase transformer modeling for analyzing transient overvoltages distribution and transference”, accepted for publication in IEEE Latin America Transactions, 2008.

° C. Tejada, P. Gómez, J. C. Escamilla, “Computation of Radio Interference Levels in High Voltage Transmission Lines with Corona”, accepted for publication in IEEE Latin America Transactions, 2008.

° P. Gómez, F. A. Uribe, “The numerical Laplace transform: an accurate tool for analyzing electromagnetic transients on power system devices”, ELSEVIER Int. Journal of Electrical Power & Energy Systems, Volume 31, Issues 2-3, Pages 116-123, February-March, 2009.

 

 

 

 

 

 
Teaching
Graduate level

° Modeling of Electrical Components for Electromagnetic Transients.                                            Regular course of the graduate program in Electrical Engineering, SEPI-ESIME-IPN 

° Numerical Techniques for Transient Analysis

Regular course of the graduate program in Electrical Engineering, SEPI-ESIME-IPN

° Electromagnetic Theory

Regular course of the graduate program in Electrical Engineering, SEPI-ESIME-IPN

Undergraduate level
° High Voltage Engineering

Regular course of the undergraduate program in Electrical Engineering, ESIME-IPN

 

 

 

 

 

 

 

 

 

 

 

 

 

 
International Conference

° P. Gómez, P. Moreno, J. L. Naredo, “Modeling Non-Linear Conditions in Transmission Network Transients Using the Numerical Laplace Transform”, North American Power Symposium (NAPS) 2002, Tempe, Arizona, U.S.A., October del 2002.

 

° P. Gómez, P. Moreno, J. L. Naredo, M. Dávila, “Frequency Domain Transient Analysis of Transmission Networks Including Non-linear Conditions”, Proc. of IEEE Bologna Power Tech International Conference (BPT’03), Bologna, Italy, June 2003.

 

° P. Gómez, P. Moreno, J. L. Naredo, M. Dávila, “Modeling of Non-Uniform Transmission Lines in the Frequency Domain”. North American Power Symposium (NAPS) 2003, Saint Louis, Missouri, U.S.A., October 2003.

 

° A. Ramirez, P. Gómez, P. Moreno, A. Gutierrez, “Frequency domain analysis of electromagnetic transients through the numerical Laplace transforms”, IEEE Power Engineering Society General Meeting 2004, vol.16-10, p.p.1136 – 1139. June 2004.

 

° N. H. Sánchez, P. Gómez, P. Moreno, J. L. Naredo, “Frequency Domain Transient Analysis of Illuminated Multiconductor Non-Uniform Lines”. North American Power Symposium (NAPS) 2004, Moscow, Idaho, U.S.A., August 2004.

 

° P. Gómez, P. Moreno, M. Dávila, J. L. Naredo, “Time Domain Analysis of Single Phase Non Uniform Lines with Frequency Dependent Electrical Parameters”. North American Power Symposium (NAPS) 2004, Moscow, Idaho, U.S.A., August 2004.

 

° M. Davila, J. L. Naredo, P. Moreno, J. A. Gutierrez, P. Gómez, “Analyzing Transients on Multiconductor Lines with Corona”, IEEE/PES T&D 2004 Latin America, Sao Paulo, Brazil. November 2004.

 

° P. Gómez, P. Moreno, J. L. Naredo, “Transient Analysis of Single Phase Non Uniform Lines with Frequency Dependent Electrical Parameters”. International Conference on Power Systems Transients (IPST’05), Montreal, Canada, June 2005.

 

° P. Moreno, P. Gómez, M. Dávila, J.L. Naredo, “A Uniform Line Model for Non-Uniform Single-Phase Lines with Frequency Dependent Electrical Parameters”, 2006 IEEE PES T&D Conference and Exposition Latin America, Caracas, Venezuela, August 2006.

 

° P. Gómez,  P. Arellano, R. O. Mota, “Frequency Domain Transient Analysis Applied to Transmission System Restoration Studies”, 7th International Conference of Power Systems Transients (IPST’07), Lyon, France, June 2007. [PDF]

 

° P. Gómez, “Validation of ATP Transmission Line Models for a Monte Carlo Study of Switching Transients”, North American Power Symposium (NAPS) 2007, Las Cruces, New Mexico, U.S.A., Sept-Oct 2007.

 

° F. P. Espino, P. Gómez, A. Reyes, “Effect of Voltage Distortion on Stress Grading Coatings Working at High Fundamental Frequency”, 2007 Electrical Insulation Conference and Electrical Manufacturing Expo, Nashville, Tennessee, USA, Octubre 2007.

 

° A. Utrilla, F. P. Espino, P. Gómez, “Analyzing the Effect of High Fundamental Frequencies in semiconductor coatings of machine windings fed by speed controllers”,  Congreso Internacional Sobre Alta Tensión y Aislamiento Eléctrico (ALTAE) 2007, Cuernavaca, Morelos, Mex., Oct-Nov 2007.

National Conference

° J. Hernández, P. Gómez, “Simulation of Electrical Arc Effects in the 3-Phase Opening of HV Breakers Using ATP/EMTP”, 9º Congreso Nacional de Ingeniería Electromecánica y de Sistemas, México, D.F., Mex, November 2006.

 

° C. Tejada, P. Gómez, G. Basilio, “Analysis of Transient Overvoltages Due to Switching of Multiconductor Transmission Lines”, 9º Congreso Nacional de Ingeniería Electromecánica y de Sistemas, México, D.F., Mex, November 2006.

 

° P. Arellano, P. Gómez, R. O. Mota, "Frequency Domain Analysis of Transient Overvoltages Applied to the Restoration of Transmission Systems”, 9º Congreso Nacional de Ingeniería Electromecánica y de Sistemas, México, D.F., Mex, November 2006.

° P. Gómez, P. Moreno, “Simplified Method of Characteristics for Transient Solution of Transmission Lines Considering Frequency Dependence and Non Uniformities”, 9º Congreso Nacional de Ingeniería Electromecánica y de Sistemas, México, D.F., Mex, November 2006.

 

° J. C. Escamilla, P. Gómez, C. Tejada, “Distributed Parameter Modeling of a Single-phase Transformer for Transient Overvoltages Transference Analysis”, 10º Congreso Nacional de Ingeniería Electromecánica y de Sistemas, México, D.F., Mex, November 2007.

 

° C. Tejada, P. Gómez, J. C. Escamilla, Analysis of Radio Interference due to Corona Effect on High Voltage Transmission Lines”, 10º Congreso Nacional de Ingeniería Electromecánica y de Sistemas, México, D.F., Mex, November 2007.

 

° P. Gómez, P. Moreno, “Numerical Laplace Transform Analysis of Signal Integrity Phenomena in High Speed Digital Systems Interconnects”, 10º Congreso Nacional de Ingeniería Electromecánica y de Sistemas, México, D.F., Mex, November 2007.

 

° J. C. Escamilla, P. Gómez, “Modeling of a Transmission Line Excited by an Indirect Lightning Stroke”, Reunión de Verano de Potencia y Aplicaciones Industriales RVP-AI/2008, Acapulco, Gro, México, July 2008.

 

° C. Tejada, P. Gómez, F. P. Espino-Cortes, “Computational Method for Radiointerference due to Corona in Transmission Lines and Attenuation Criteria”, Reunión de Verano de Potencia y Aplicaciones Industriales RVP-AI/2008, Acapulco, Gro, México, July 2008.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Departamento de Ingeniería Eléctrica

Sección de Estudios de Posgrado e Investigación, ESIME - IPN
U. P. Adolfo López Mateos; Edificio Z-4 Primer piso
C. P. 07738 Zacatenco, México D. F. MÉXICO
Tel: (55) 57 29 60 00 ext. 54852. Fax: Ext.54218