Crystal Wash :
1 Carriers stacked in bottom possibly dampening ultrasonic energy.
2 Carriers are made of Teflon? , could a stainless steel carrier enhance the ultrasonic energy?
3 What is the particulate levels on the crystal blanks is this an issue? Being trapped by carriers?
4 Has an inspection been done on the crystal blanks to look for particulate or residual?
5 What is the resistivity of the DI water for the final rinse?
6 What ultrasonic frequency is being used ?
Baseplate:
1 How close to actual frequency is the baseplating being done?
2 What is the range coming out of Baseplate? Approx. 1500ppm
3 What is the thickness of the NiCr layer plated prior to Gold?
4 What is the range going into Baseplate?
5 What is the plating rate?
6 Monitor crystal not reading correctly?  Short on the wire going to the monitor crystal
7 How often is the monitor crystal changed?  (6 Mhz?)
Xtal Mount:
1 Does eliminating brush wash after Mount change the aging data?
2 Is brush wash effective at removing particulate from both sides of the crystal?
3
4
Finish Plate:
1 Sticks being returned to Transat to be looked at (design issue with sticks, thermal coupling)
2 Finish Plater gaining capacitance causing crystals to read ok but are actually high in frequency
Miscellaneous:
1 What kind of data is being taken in process and how is it used? Any yield tracking?
2 Is there some type of identifier in process which correlates to the aging data?
3 Square packages had a lot of leakers, Finish Plate fixture needs to be redone so that
units can be read easier and aren't so tight in fixture. (bent flange)