ASTM D 1921 :
Standard Test Methods for Particle Size (Sieve
Analysis) of Plastic Materials |
|
These test methods
cover the measurement of the particle size of plastic
materials in the powdered, granulard, or pelleted forms
in wich they are commonly supplied. As these test methods
utilize dry sieving, the lower limit of measurement is
considered to be about 38 microns (No 400 sieve). For
smaller particle sizes, sedimentation methods are
recommended.
Two test methods
are described :
- Test method A
: This test method uses multiple sieves selected
to span the particle size of the material. The
mean particle diameter and distribution can be
determined by this test method.
- Test method B
: This test method is an abbreviated version of
Test Method A conducted with a few specific
sieves. This test method determines "percent
passing" or "percent retained" on
a given sieve. Test Method B is applicable to
materials wich do not have a normal particle size
distribution suchs as pellets and cubes.
The values as
stated in inch-pound units are to be regarded as the
standard. The values given in parentheses are given for
information only.
|