Prevent the occurrence of fire and explosion. |
|
|
Reduce the risk of life caused by fire. |
|
|
Reduce the risk of damage caused by fire to the ship, its cargo and the environment. |
|
|
Contain, control and suppress fire and explosion in the compartment of origin. |
|
|
Provide adequate and readily accessible means of escape for passengers and crews. |
Definitions
Divisions formed by bulkheads and decks which comply following regulations:
|
|
Constructed of steel or other equivalent material. | ||||||
|
|
Suitably stiffened. | ||||||
|
|
Insulated with approved non-combustible materials such as
|
| Class A-60 | 60 min |
| Class A-30 | 30 min |
| Class A-15 | 15 min |
| Class A-0 | 0 min. |
|
|
Constructed as to be capable of preventing the passage of smoke and flame to the end of the one hour standard fire test. |
|
|
A test is required as per FTP code. |
|
|
Sections into which the hull, superstructure and deckhouses are divided by A-class divisions. |
|
|
Mean length and width of which on any deck does not in general exceed 40m. |
|
|
Required for ships 500GT and upwards. |
|
|
At least one. |
|
|
Specifications as per FSS code. |
|
|
Can be used on either side of the ship. |
|
|
Ships shall be provided with independently driven fire pimps.
|
||||||||||||
|
|
An emergency fire pump for cargo ships and passenger ships less than 1000GT, if fire in any compartment cause all the pumps inoperative. |
|
|
Non perishable material. |
|
|
At least 10m length. |
|
|
Not more than 15m in machinery space. |
|
|
Not more than 20m in other spaces and open decks. |
|
|
Not more than 25m for open decks for ships with max breadth more than 30m. |
|
|
Complete interchangeability of hose, couplings and nozzles, unless one hose and nozzle for each hydrant is provided. |
|
|
For cargo ships 1000GT and upwards, 1 for every 30m and 1 spare (not less than 5). |
|
|
This no. does not include E/R or boiler room. |
|
|
Nozzle size: 12mm, 16mm and 19mm or as near as thereto. |
|
|
Dual purpose type (jet and spray). |
|
|
Comply with FSS code. |
|
|
Of appropriate type and sufficient number. |
|
|
For ships of 1000GT and upwards: carry at least 5 extinguishers. |
|
|
Near entrance of an space. |
|
|
Carbon di oxide shall not be placed in accommodation spaces. |
|
|
Non-conductive extinguishing medium for control spaces and electrical spaces. |
|
|
Ready for use and placed at easily visible places. |
|
|
Spare charges: 100% for first 10 and 50% of remainder. |
|
|
Additional fire extinguishers, which cannot be recharged. |
|
|
Comply with FSS code. |
|
|
Ships to carry at least two. |
|
|
Passenger ships: additional 1 for every 80m and part thereof, of the aggregate of all passenger spaces and service spaces. |
|
|
If carrying more than 36 passengers, 2 additional outfit for each main vertical zone. |
|
|
Tankers: two additional. |
|
|
Two spare charges for each breathing apparatus. |
|
|
The crews shall have necessary knowledge and skills to handle fire. |
|
|
Crew members shall receive instructions regarding fire safety, duties. |
|
|
Parties for fire fighting to be organized. |
|
|
Crew members shall be trained regarding fire fighting. |
|
|
Their performance to be evaluated. |
|
|
Training manuals to be provided in each crew mess room and recreation room or in each crew's cabin. | ||||||||||||||
|
|
To be written in working language of the ship. | ||||||||||||||
|
|
Will contain instructions easily understood and illustrated wherever possible. | ||||||||||||||
|
|
Training manuals should explain followings in details:
|
|
|
General arrangement plans shall be permanently exhibited for the guidance of ship's officers. | ||||||||||||||||||
|
|
GA plans will show for each deck:
|
||||||||||||||||||
|
|
The details may be may be set out in a booklet, if approved by director.
|
||||||||||||||||||
|
|
Plans and booklets to be kept updated. | ||||||||||||||||||
|
|
Alterations to be recorded as soon as possible. | ||||||||||||||||||
|
|
Descriptions in these booklets to be in language(s) required by the authority. | ||||||||||||||||||
|
|
Duplicate set of fire control plans shall be permanently stored in a prominently marked weathertight enclosure outside the deckhouse for shore side fire fighting personnel. |
Carriage of dangerous goods
|
|
Water supplies. |
|
|
Source of ignition. |
|
|
Detection system. |
|
|
Ventilation. |
|
|
Bilge pumping. |
|
|
Personnel protection. |
|
|
Portable fire extinguishers. |
|
|
Insulation of machinery space boundaries. |
|
|
Water spray system. |
|
|
Separation of ro-ro spaces. |
|
|
An appropriate document issued by the director on an authorized organization. |
|
|
Evidence of compliance of construction and equipment with the requirements of this regulation. |
|
|
Shall be carried onboard. |