Prevent the occurrence of fire and explosion. |
![]() |
Reduce the risk of life caused by fire. |
![]() |
Reduce the risk of damage caused by fire to the ship, its cargo and the environment. |
![]() |
Contain, control and suppress fire and explosion in the compartment of origin. |
![]() |
Provide adequate and readily accessible means of escape for passengers and crews. |
Definitions
Divisions formed by bulkheads and decks which comply following regulations:
![]() |
Constructed of steel or other equivalent material. | ||||||
![]() |
Suitably stiffened. | ||||||
![]() |
Insulated with approved non-combustible materials such as
|
Class A-60 | 60 min |
Class A-30 | 30 min |
Class A-15 | 15 min |
Class A-0 | 0 min. |
![]() |
Constructed as to be capable of preventing the passage of smoke and flame to the end of the one hour standard fire test. |
![]() |
A test is required as per FTP code. |
![]() |
Sections into which the hull, superstructure and deckhouses are divided by A-class divisions. |
![]() |
Mean length and width of which on any deck does not in general exceed 40m. |
![]() |
Required for ships 500GT and upwards. |
![]() |
At least one. |
![]() |
Specifications as per FSS code. |
![]() |
Can be used on either side of the ship. |
![]() |
Ships shall be provided with independently driven fire pimps.
|
||||||||||||
![]() |
An emergency fire pump for cargo ships and passenger ships less than 1000GT, if fire in any compartment cause all the pumps inoperative. |
![]() |
Non perishable material. |
![]() |
At least 10m length. |
![]() |
Not more than 15m in machinery space. |
![]() |
Not more than 20m in other spaces and open decks. |
![]() |
Not more than 25m for open decks for ships with max breadth more than 30m. |
![]() |
Complete interchangeability of hose, couplings and nozzles, unless one hose and nozzle for each hydrant is provided. |
![]() |
For cargo ships 1000GT and upwards, 1 for every 30m and 1 spare (not less than 5). |
![]() |
This no. does not include E/R or boiler room. |
![]() |
Nozzle size: 12mm, 16mm and 19mm or as near as thereto. |
![]() |
Dual purpose type (jet and spray). |
![]() |
Comply with FSS code. |
![]() |
Of appropriate type and sufficient number. |
![]() |
For ships of 1000GT and upwards: carry at least 5 extinguishers. |
![]() |
Near entrance of an space. |
![]() |
Carbon di oxide shall not be placed in accommodation spaces. |
![]() |
Non-conductive extinguishing medium for control spaces and electrical spaces. |
![]() |
Ready for use and placed at easily visible places. |
![]() |
Spare charges: 100% for first 10 and 50% of remainder. |
![]() |
Additional fire extinguishers, which cannot be recharged. |
![]() |
Comply with FSS code. |
![]() |
Ships to carry at least two. |
![]() |
Passenger ships: additional 1 for every 80m and part thereof, of the aggregate of all passenger spaces and service spaces. |
![]() |
If carrying more than 36 passengers, 2 additional outfit for each main vertical zone. |
![]() |
Tankers: two additional. |
![]() |
Two spare charges for each breathing apparatus. |
![]() |
The crews shall have necessary knowledge and skills to handle fire. |
![]() |
Crew members shall receive instructions regarding fire safety, duties. |
![]() |
Parties for fire fighting to be organized. |
![]() |
Crew members shall be trained regarding fire fighting. |
![]() |
Their performance to be evaluated. |
![]() |
Training manuals to be provided in each crew mess room and recreation room or in each crew's cabin. | ||||||||||||||
![]() |
To be written in working language of the ship. | ||||||||||||||
![]() |
Will contain instructions easily understood and illustrated wherever possible. | ||||||||||||||
![]() |
Training manuals should explain followings in details:
|
![]() |
General arrangement plans shall be permanently exhibited for the guidance of ship's officers. | ||||||||||||||||||
![]() |
GA plans will show for each deck:
|
||||||||||||||||||
![]() |
The details may be may be set out in a booklet, if approved by director.
|
||||||||||||||||||
![]() |
Plans and booklets to be kept updated. | ||||||||||||||||||
![]() |
Alterations to be recorded as soon as possible. | ||||||||||||||||||
![]() |
Descriptions in these booklets to be in language(s) required by the authority. | ||||||||||||||||||
![]() |
Duplicate set of fire control plans shall be permanently stored in a prominently marked weathertight enclosure outside the deckhouse for shore side fire fighting personnel. |
Carriage of dangerous goods
![]() |
Water supplies. |
![]() |
Source of ignition. |
![]() |
Detection system. |
![]() |
Ventilation. |
![]() |
Bilge pumping. |
![]() |
Personnel protection. |
![]() |
Portable fire extinguishers. |
![]() |
Insulation of machinery space boundaries. |
![]() |
Water spray system. |
![]() |
Separation of ro-ro spaces. |
![]() |
An appropriate document issued by the director on an authorized organization. |
![]() |
Evidence of compliance of construction and equipment with the requirements of this regulation. |
![]() |
Shall be carried onboard. |