Paramètres related to :

Coordinate System

 

Symbol

Param

Bit

Description

 

SCW

0001

0

0= Least command incr. Is Metric;   1= Inch.

PPD

0002

1

Relative coord. Value is preset when abs. Is set.

APRS

0010

7

1= Coord. Value (para. 708/711) is enter at ref. point.

APCX8

0021

5

1= Absolute puls coder is optioned;  0=No optioned.

APCX7

0021

4

1= Absolute puls coder is optioned;  0=No optioned.

APC4

0021

3

1= Absolute puls coder is optioned;  0=No optioned.

APCZ

0021

2

1= Absolute puls coder is optioned;  0=No optioned.

APCY

0021

1

1= Absolute puls coder is optioned;  0=No optioned.

APCX

0021

0

1= Absolute puls coder is optioned;  0=No optioned.

ABS8

0022

5

1= Ref. Point Pos. In abs Pilse coder is settled.

ABS7

0022

4

1= Ref. Point Pos. In abs Pilse coder is settled.

ABS4

0022

3

1= Ref. Point Pos. In abs Pilse coder is settled.

ABSZ

0022

2

1= Ref. Point Pos. In abs Pilse coder is settled.

ABSY

0022

1

1= Ref. Point Pos. In abs Pilse coder is settled.

ABSX

0022

0

1= Ref. Point Pos. In abs Pilse coder is settled.

CLCL

0024

6

1= Local Coord. Sys. Cancel by auto. Ref. point return.

UWKZ

0024

5

Work zero shift :  1= Change abs. Coord;  0=Doesn’t

LII10

0024

1

Inpt/outpt unit is :  1= 0.01mm/0.001’’   0= 0.001mm/0.0001’’

EX10D

0028

5

1= Ext. Work Coord. Shift is multiplied by 10 times.

NUABS

0045

5

1= Return to same status before machine lock was on.

PRSTIN

0063

1

1= In inch auto. Coord. Setting is done by prms 815/818.

MTDSPI

0063

0

1= Mach. Coord. Sys. Is display to meet the input system (mm/inch).

PRSX

0708

 

Coordinate value of the refer. Point of X axis.

PRSY

0709

 

Coordinate value of the refer. Point of Y axis.

PRSZ

0710

 

Coordinate value of the refer. Point of Z axis.

PRS4

0711

 

Coordinate value of the refer. Point of 4th axis.

REF2X

0735

 

Distance from the Ref. point to the 2nd Ref. Point.

REF2Y

0736

 

Distance from the Ref. point to the 2nd Ref. Point.

REF2Z

0737

 

Distance from the Ref. point to the 2nd Ref. Point.

REF24

0738

 

Distance from the Ref. point to the 2nd Ref. Point.

ABSXP

0739

 

Counter Data at Ref. point when abs. Coder is used.

ABSYP

0740

 

Counter Data at Ref. point when abs. Coder is used.

ABSZP

0741

 

Counter Data at Ref. point when abs. Coder is used.

ABS4P

0742

 

Counter Data at Ref. point when abs. Coder is used.

EXOFS1

0751

 

Amount of external Work zero point shift on X axis.

EXOFS2

0752

 

Amount of external Work zero point shift on Y axis.

EXOFS3

0753

 

Amount of external Work zero point shift on Z axis.

EXOFS4

0754

 

Amount of external Work zero point shift on 4th axis.

ZOF1S1

0755

 

1st Work zero point amount on X axis (G54).

ZOF1S2

0756

 

1st Work zero point amount on Y axis (G54).

ZOF1S3

0757

 

1st Work zero point amount on Z axis (G54).

ZOF1S4

0758

 

1st Work zero point amount on 4th axis (G54).

ZOF2S1

0759

 

2nd Work zero point amount on X axis (G55).

ZOF2S2

0760

 

2nd Work zero point amount on Y axis (G55).

ZOF2S3

0761

 

2nd Work zero point amount on Z axis (G55).

ZOF2S4

0762

 

2nd Work zero point amount on 4th axis (G55).

ZOF3S1

0763

 

3rd Work zero point amount on X axis (G56).

ZOF3S2

0764

 

3rd Work zero point amount on Y axis (G56).

ZOF3S3

0765

 

3rd Work zero point amount on Z axis (G56).

ZOF3S4

0766

 

3rd Work zero point amount on 4th axis (G56).

ZOF4S1

0767

 

4th Work zero point amount on X axis (G57).

ZOF4S2

0768

 

4th Work zero point amount on Y axis (G57).

ZOF4S3

0769

 

4th Work zero point amount on Z axis (G57).

ZOF4S4

0770

 

4th Work zero point amount on 4th axis (G57).

ZOF5S1

0771

 

5th Work zero point amount on X axis (G58).

ZOF5S2

0772

 

5th Work zero point amount on Y axis (G58).

ZOF5S3

0773

 

5th Work zero point amount on Z axis (G58).

ZOF5S4

0774

 

5th Work zero point amount on 4th axis (G58).

ZOF6S1

0775

 

6th Work zero point amount on X axis (G59).

ZOF6S2

0776

 

6th Work zero point amount on Y axis (G59).

ZOF6S3

0777

 

6th Work zero point amount on Z axis (G59).

ZOF6S4

0778

 

6th Work zero point amount on 4th axis (G59).

REF3X

0780

 

Distance of 3rd Ref. Pnt to 1st Ref. Pnt on X axis.

REF3Y

0781

 

Distance of 3rd Ref. Pnt to 1st Ref. Pnt on Y axis.

REF3Z

0782

 

Distance of 3rd Ref. Pnt to 1st Ref. Pnt on Z axis.

REF34

0783

 

Distance of 3rd Ref. Pnt to 1st Ref. Pnt on 4th axis.

REF4X

0784

 

Distance of 4rd Ref. Pnt to 1st Ref. Pnt on X axis.

REF4Y

0785

 

Distance of 4rd Ref. Pnt to 1st Ref. Pnt on Y axis.

REF4Z

0786

 

Distance of 4rd Ref. Pnt to 1st Ref. Pnt on Z axis.

REF44

0787

 

Distance of 4rd Ref. Pnt to 1st Ref. Pnt on 4th axis.

PRSTIX

0815

 

Coordinate value of X ref. Pnt. In inch programming.

PRSTIY

0816

 

Coordinate value of Y ref. Pnt. In inch programming.

PRSTIZ

0817

 

Coordinate value of Z ref. Pnt. In inch programming.

PRSTI4

0818

 

Coordinate value of 4th ref. Pnt. In inch programming.

PRS7

0825

 

Coordinate value of the Ref. point of the 7th axis.

PRS8

0826

 

Coordinate value of the Ref. point of the 8th axis.

ABS7P

0827

 

Data value at Ref. Pnt. For Abs. Pulse coder (7th).

ABS8P

0828

 

Data value at Ref. Pnt. For Abs. Pulse coder (8th).

SCWS

7001

0

0= Least command incr. Is Metric;  1= Inch (5th/6th axis).

APRSS

7010

7

1= Sets auto. Coord. At Ref. Pnt Return (5th/6th axis).

APC6

7021

1

1= Absolute Pulse coder is optioned  0= No Optioned.

APC5

7021

0

1= Absolute Pulse coder is optioned  0= No Optioned.

ABS6

7022

1

1= Ref. Point Pos. In Abs. Pulse coder is settled.

ABS5

7022

0

1= Ref. Point Pos. In Abs. Pulse coder is settled.

PRS5

7708

 

Coordinate value of the refer. Point of 5th axis.

PRS6

7709

 

Coordinate value of the refer. Point of 6th axis.