Paramètres
related to :
Symbol |
Param |
Bit |
Description |
||
DCS |
0001 |
2 |
1= Cycle start by start key on MDI panel. |
||
EBCL |
0010 |
1 |
1= EOB code by « * »; 0= EOB code by « ; ». |
||
INHM |
0013 |
4 |
1= Menu programming inefective; 0= Menu programming effective. |
||
CBLNK |
0015 |
0 |
1= Cursor blinks; 0= Cursor doesn’t blink. |
||
CPRD |
0015 |
7 |
1= Set to mm or inch if dec. Point is omitted 0= Least inp. Incr. |
||
NPRD |
0016 |
3 |
1= Inp. And display without dec. Point,; 0= With dec. Point. |
||
OPG7 |
0017 |
6 |
1= Feed hold actuated with soft. Operator’s panel. |
||
OPG6 |
0017 |
5 |
1= Protect key actuated with soft. Operator’s panel. |
||
OPG5 |
0017 |
4 |
1= Opt-blk-skip, Sing-blk, Mach-lock, D-run. Actuated soft Panel. |
||
OPG4 |
0017 |
3 |
1= Jog-fdrate, Overr, Raptrvse Overr. Actuated soft. Panel. |
||
OPG3 |
0017 |
2 |
1= Axis select, Man. Puls Generator. Actuated soft Panel. |
||
OPG2 |
0017 |
1 |
1= Jogfd axis select, Jograptravers. Actuated soft Panel. |
||
OPG1 |
0017 |
0 |
1= Mode Select Actuated with soft Operator’s Panel. |
||
EDITB |
0018 |
7 |
1= Edit B is effective; 0= Edit is standard. |
||
DSPN |
0023 |
6 |
1= The CRT screen is displayed in Spanish. |
||
DHNG |
0023 |
5 |
1= The CRT screen is displayed in Hangeul. |
||
DITA |
0023 |
4 |
1= The CRT screen is displayed in Italian. |
||
DCHI |
0023 |
3 |
1= The CRT screen is displayed in Chinese. |
||
DFRN |
0023 |
2 |
1= The CRT screen is displayed in French. |
||
DGRM |
0023 |
1 |
1= The CRT screen is displayed in German. |
||
DJPN |
0023 |
0 |
1= The CRT screen is displayed in Japanese. |
||
MMDL |
0028 |
3 |
1= Modal status is displayed in MDI operation B. |
||
DACTF |
0028 |
2 |
1= Act. Speed is display on current position and prgm Check.. |
||
PRCMSG |
0028 |
1 |
Display on Prgrm Check Screen 1= PMC-MES. 0= Rem. Motion. |
||
PRCPOS |
0028 |
0 |
Display on prgrm Check Screen 1= Abs. Coor. 0= Rel. Coor. |
||
NDSP4 |
0035 |
3 |
1= The current position of 4th axis is not displayed. |
||
NDSPZ |
0035 |
2 |
1= The current position of Z axis is not displayed. |
||
NDSPY |
0035 |
1 |
1= The current position of Y axis is not displayed. |
||
NDSPX |
0035 |
0 |
1= The current position of X axis is not displayed. |
||
FLKY |
0038 |
3 |
1= CRT/MDI Keyboard uses a full key. |
||
SORT |
0040 |
4 |
Prgrm-Library is displayed in : 1= Num. Order 0= Norm. Order. |
||
NAMPR |
0040 |
0 |
1= Displays prgrm Name on the directory Display. |
||
CLER |
0045 |
6 |
RST. PB. Selects : 1= Clear 0= Reset Conditions |
||
MBCLR |
0057 |
7 |
1= MDI-B Prgrm is cleared by the reset operation. |
||
IGNCOL |
0060 |
7 |
9’’ High-Resolution Display 1= Color, 0= Monochrome. |
||
C14DGN |
0060 |
3 |
Diagnose Screen 1= 14’’, 0= 9’’ |
||
ALL78 |
0061 |
7 |
1= 7th & 8th axse Display in common position Display. |
||
DSP78 |
0061 |
6 |
1= 7th & 8th Axes display in Abs. & Rel. Position Coord. |
||
MTDSPI |
0063 |
0 |
1= Machine coor. Sys. Displ. To meet the input systeme. |
||
NPA |
0064 |
5 |
1= Screen is not switched to the Alarm/Message Page |
||
SETREL |
0064 |
0 |
1= Preset is made for each axis in Rel. Pos. Display. |
||
UPKY |
0130 |
|
Set Jogfeed axes & Dir. On Software Operator’s Panel. |
||
DWNKY |
0131 |
|
Set Jogfeed axes & Dir. On Software Operator’s Panel. |
||
RGTKY |
0132 |
|
Set Jogfeed axes & Dir. On Software Operator’s Panel. |
||
LFTKY |
0133 |
|
Set Jogfeed axes & Dir. On Software Operator’s Panel. |
||
FWDKY |
0134 |
|
Set Jogfeed axes & Dir. On Software Operator’s Panel. |
||
BACKY |
0135 |
|
Set Jogfeed axes & Dir. On Software Operator’s Panel. |
||
RTDKY |
0136 |
|
Set Jogfeed axes & Dir. On Software Operator’s Panel. |
||
LTYLY |
0137 |
|
Set Jogfeed axes & Dir. On Software Operator’s Panel. |
||
NSW11 |
0140 |
|
Set the names of Genral Purpose Switches on Software Ope. Panel. |
||
NSW88 |
0203 |
|
Set the names of Genral Purpose Switches on Software Ope. Panel. |
||
|
|
|
|
||