Paramètres related to :

Programs.

 

Symbol

Param

Bit

Description

 

PRG9

0010

4

1= Prgrm and Sub-prgrm from 9000 to 9999 are protected.

 

G01

0011

6

1= G01 Mode at power on;   0= G00 Mode at power on.

 

SBKM

0011

5

1= Single block active in macros;   0= Not active.

 

CPRD

0015

7

1= If no decimal point, unit is mm or inch;   0= Least input incr.

 

REP

0015

6

1= New entered prgrm replace old one;   0= Doesn’t replace, alarm.

 

SUPM

0016

2

1= Start up B type type effective with Cut. Comp.   0= Not effective

 

SQTYP

0018

4

Program restart should be :   1= R type;   0= P or Q type.

 

M02NR

0019

5

1= Return to head of program after executing M02.

 

G91

0030

7

When power on :   1= G91;   0= G90 Mode is set.

 

SSCA1

0041

5

Set the reference axis for C.S.S. Calculation.

 

SSCA0

0041

4

Set the reference axis for C.S.S. Calculation.

 

DAT16M

0055

6

Set the data distribution time (msec) of G05.

 

DAT4MS

0055

5

Set the data distribution time (msec) of G05.

 

DAT2MS

0055

4

Set the data distribution time (msec) of G05.

 

ITPCNT

0055

5

Interpolation time in high speed cycle machining.

 

MIC

0057

3

1= At omission of Decimal point, min. unit x 10.

 

M3B

0065

7

1= Max. 3 M codes can be designated in one block.

 

MBUF1

0111

 

Set the 1st M Code not subject to buffering.

 

MBUF2

0112

 

Set the 2nd M Code not subject to buffering.

 

PSRNQ1

0124

 

Order of movement to DNR restart position in prgrm of X axis.

 

PSRNQ2

0125

 

Order of movement to DNR restart position in prgrm of Y axis.

 

PRSNQ3

0126

 

Order of movement to DNR restart position in prgrm of Z axis.

 

PRSNQ4

0127

 

Order of movement to DNR restart position in prgrm of 4th axis.

 

INTPLN

0212

 

0= G17   1= G18   2= G19 is select at power on.

 

SEQINC

0550

 

Increment value on automatic insertion of sequence number.

 

G05NOM

0597

 