HOME |
| |
BACK |
|
DIGITAL DELAY GENERATOR (30ns to 5 ms)
|
|
OE-DD-A1-PS-TC
|
Single and dual channel models
GPIB control available
30 ns to 1 µs delays
30 ns to 9.999 µs delays
30 ns to 999.999 µs delays
100 ns to 5 ms delays
Jitter as low as 40 ps
Fixed or variable output pulse width
TTL signal levels
Will drive 50 Ohm loads
The four models in the OE-DD-A digital delay generator
series feature low-jitter adjustable delays in the range of 30 ns to 1 µs
(Model OE-DD-A4-PS), 30 ns to 9.999 µs (Model OE-DD-A1-PS),
100 ns to 999.999 µs (Model OE-DD-A2-PS) and 100 ns to 5.0 µs
(Model OE-DD-A3-PS). All models are available in single or dual output channel
versions. Dual output units feature two independent delay controls.
|
OE-DD-A3-PS
|
Model |
AVX-DD-A1-PS |
AVX-DD-A2-PS |
No. of output channels: |
One standard
Two optional1 |
One standard
Two optional1 |
Delay control: |
Thumbwheel |
Thumbwheel |
GPIB: |
N/A |
N/A |
Variable delay range: |
0 to 9.999 µs |
0 to 999.999 µs |
Delay resolution: |
1 ns 0.1 ns optional5 |
1 ns 0.1 ns optional5 |
Jitter (RMS): (Ext trig in to pulse out) |
± 40 ps ± 0.0005% of
delay. ± 40 ps |
Insertion delay: |
30 ns (35 ns for 0.1 ns resolution option) |
Rise time, fall time: |
< or = 10 ns |
Update time: |
N/A |
N/A |
Display: |
Thumbwheel |
Thumbwheel |
Output amplitude: |
+3V (TTL) will drive 50 Ohm loads |
Trigger required: |
+ 5 Volt, PW > 50 ns |
OUT pulse width: |
100 ns to 1 µs, one-turn control |
Max duty cycle: |
80% |
PRF: |
0 to 5 MHz |
0 to 1 MHz |
Connectors: |
BNC |
Power requirement: |
110/220 Volts (switchable) 50 - 60 MHz |
Dimensions: (H x W x D) |
100 mm x 215 mm x 375 mm
(3.9" x 8.5" x 14.8") |
Model |
AVX-DD-A3-PS |
AVX-DD-A4-PS |
No. of output channels: |
One standard
Two optional1 |
One standard
Two optional1 |
Delay control: |
Front-panel keypad, GPIB, or RS-232 |
ten-turn control standard, GPIB optional |
GPIB: |
OP1B standard2 |
OP1 optional3 |
Variable delay range: |
0 to 5 ms |
0 to 1.0 µs |
Delay resolution: |
varies, < 0.3% of (delay + 20 ns) |
4 ns |
Jitter (RMS): (Ext trig in to pulse out) |
± 0.015% of delay.
± 40 ps |
± 0.0025% of delay. |
Insertion delay: |
100 ns |
30 ns |
Rise time, fall time: |
< or = 10 ns |
Update time: |
< or = 150 ms (typical)4 |
30 ms |
Display: |
4 line 40 character back lit LCD display |
Ten-turn 4 ns increments control |
Output amplitude: |
0 to ± 5 V (variable) will drive 50 W loads |
+3V (TTL) will drive 50 W loads |
Trigger required: |
+ 5 Volt, PW > 50 ns |
OUT pulse width: |
50 ns to 5 ms (variable) |
250 ns (fixed) |
Max duty cycle: |
80% |
PRF: |
0 to 10 MHz |
0 to 1 MHz |
Connectors: |
BNC |
Power requirement: |
110/220 Volts (switchable) 50 - 60 MHz |
Dimensions: (H x W x D) |
100 mm x 430 mm x 375 mm
(3.9" x 17" x 14.8") |
- To specify the two output channel option, add the suffix -TC to the model number.
- Click here for a description of the OP1B features.
- See below for a description of -OP1 option. To specify this GPIB option, add the suffix
-OP1 to the model number.
- Valid for single-channel model only.
- To specify the 0.1 ns resolution option, add the suffix -HR to the model number.
-OP1 OPTION
The -OP1 option is a low-cost limited feature IEEE-488 GPIB interface
which provides the following features: SH0, AH1, T0, TE0, L2, LE0, SR0, RL0, PP0, DC2,
DT0, C0 (Bus listener only).
The -OP1 option places an interface card in the pulser which provides 8-bit control
of amplitude, pulse width, pulse repetition frequency and delay when the rear-panel
LOCAL-REMOTE switch is in the REMOTE position and a GPIB cable connects to a PC with
an IEEE-488 controller board. The output pulse waveform characteristics are remotely controllable
using the mnemonics V, W, R, D or A which respectively represent pulse amplitude (Volts), pulse
width (µs), repetition rate (Hertz), delay from sync (µs) or advance before sync
(µs). Integer numbers are used (instead of exponential notation). To specify this option,
add the suffix -OP1 to the model number. Note that the -OP1 option includes the GPIB cable.
|
FRONT PANEL OF TYPICAL AVTECH -OP1 OPTION UNIT. FRONT PANEL
CONTROLS ARE ACTIVE ONLY WHEN THE REAR PANEL LOCAL-REMOTE SWITCH IS IN
THE LOCAL POSITION
|
REAR PANEL OF THE TYPICAL AVTECH -OP1 OPTION UNIT. FOR COMPUTER
CONTROL, PLACE LOCAL-REMOTE SWITCH IN REMOTE POSITION AND CONNECT A GPIB
CABLE BETWEEN THE GPIB CONNECTOR AND YOUR PC (EQUIPPED WITH A NATIONAL
CONTROLLER BOARD)
|
Our application engineers and technical staff will
be happy to help you with any further enquiries. Monday through
Friday, 9 am to 6 pm, Singapore Standard Time, call (65)-4409746 or email us
anytime at smart_sense@yahoo.com. We response within
24 hours.
|