Procedure to Receive PDO Tape
- Sign onto SMP/E
- Choose option 5 – Receive
- Verify SMPCSI global is correct and press <enter>
- Choose option 5 – CBPDO tape
- Choose option 6 – receive all or user specified SYSMODs and HOLDDATA
- Enter first <vol ser>
- Enter <tape> in tape unit type and press <enter>
- Enter <vol sers> of all tapes and press <PF3>
- Enter <sourceid>
- Verify RECEIVE HOLDATA and RECEIVE SYSMODS is yes and press <enter>
- Press <PF3>
- Press <PF3>
- Choose option E – Edit
- Add <region=5m,> to EXEC card
- Add <expdt=98000> to LABEL=(?,SL)
- Press <PF3>
- Choose option S – Submit