<- Tillbaka

Startkoder, DKC

Välj kod:

-0 E4
-1 E5
-2  
-3  
-4  
-5  
-6  
E1  
E2  
E3  
 

4.3 Diagnostic messages for basic initialization and after fatal System errors


Diagnostic Message Display: -0

The writable data storage of the drive controller is tested for its functional capability. If an error is detected, this display will remain.


Diagnostic Message Display: -1

The hardware of the amplifier is beig initialized.


Diagnostic Message Display: -2

Cause:

The control supply voltage of the encoder is missing.

Remedy:

Exchange the hardware.


Diagnostic Message Display: -3

Initializing the parameters from the NovRam and calculating the respective data depending from the parameter contents.


Diagnostic Message Display: -4

Initializing and checking the command communication.


Diagnostic Message Display: -5

Initializing the system control.


Diagnostic Message Display: -6

Starting the system control.


Diagnostic Message Display: E1

Cause:

Processor fault, caused by static discharge, program error or hardware fault. More information is available via a terminal connected to the RS-232 interface.

Remedy:

Switch the amplifier off and on again; if the fault is still present, exchange the hardware. In any case inform the customer service.


Diagnostic Message Display: E2

Cause:

Test of the RAM on the programming module has shown an error. RAM defective or not plugged properly.

Remedy:

Switch off, check the plug connection and switch on again; if the error happens agains, exchange the firmware module.


Diagnostic Message Display: E3

Cause:

Caused by a hardware fault or by a static discharge, the 1 st watchdog of the amplifier has triggered.

Remedy:

Switch the amplifier off and on again; if E3 appears again, exchange the amplifier. In any case inform the customer service. Please explain the exact circumstances under which the error occurred.


Diagnostic Message Display: E4

Cause:

Caused by a hardware fault or by a static discharge, the 2 nd watchdog of the amplifier has triggered.

Remedy:

Switch the amplifier off and on again; if E4 appears again, exchange the amplifier. In any case inform the customer service.


Diagnostic Message Display: E5

Cause:

Test of the dual-port-RAM for command communication failed. Maybe the hardware for command communication is not plugged on properly.

Remedy:

Check the plug connection; if OK, exchange the amplifier.