<- Tillbaka

Statuskoder, DIAX04

Välj kod:

Ab
AF
AH
AS
bb
P0
P1
P2
P3
bb

"read for operation"

The drive is ready to be turned on.

Diagnostic message text:

Ready to be turned on (ready for operation)


Ab

"Drive is ready"

The control and power components of the drive are ready for operation.

Diagnostic message text:

Control and power components are ready (drive is ready)


AF

"Drive enable"

The drive enable was issued and operated the activation of the drive.

This follows a command value input.

Diagnostic message text:

according to selected operating mode.


AS

"Drive interlock"

The power output was locked. This signal serves the secured torque free

switching of the drive independent from existing operating states of the

drive packs.

Diagnostic message text:

Drive interlock


AH

"Drive Halt"

The drive will be stopped under the conditions of the acceleration

parameter and stays in control.


P0

Phase 0

The drive is in phase 0 and is waiting on the phase transition from phase

0 to phase 1.

Diagnostic message text:

Phase 0


P1

Phase 1

The transition from phase 1 to phase 2 was still not initiated from the

control system.

Remedy:

see the control handbook


P2

Phase 2

Before the control system switches in the communications phase 3, the

controller checks inputted parameters for content of the input limits and

for completeness. If invalid parameter values were found, the phase

progression switch will stop the drive.

Note: The parameters are not checked for exactness.

Remedy:

In the parameter "Identification Number List Invalid Operating Data

Communications Phase 2", the ID numbers S-0-0021 are recorded which

were recognized as invalid from the drive before the phase progression

switch in communications phase 3. The completion of this parameter is

required in order for switching into communications phase 3.


P3

Phase 3

Before the control system switches in the communications phase 4, the

controller checks inputted parameters for content of the input limits and

for completeness. If invalid parameter values are recognized, the phase

progression switch will be stopped by the controller.

Note: The parameters are not checked for exactness.

Remedy:

In the parameter "ID Number Lists of Invalid Operating Data

Communications Phase 3", ID number S-0-0022 records the parameters

which were recognized as invalid by the drive before the phase

progression switch in communications phase 4. The completion of this

parameter is required in order for switching into communications phase

4.