72178G08 (SDB2) Revision History |
|
|
|
Revision |
ECO # |
DESCRIPTION |
|
|
|
A |
30551 |
Released PWA, PWB, and related drawings. |
|
|
|
B |
30534 |
HW change for interrupt software, never seen in the field |
|
|
|
C |
30767 |
New artwork RevB to eliminate reworks |
|
|
|
D |
30780 |
Upate the Revision resistors for previous ECO |
|
|
|
E |
31051 |
IDMA diag bus arbitration errors & SDMA failures at high rate data. |
|
|
|
F |
31084 |
Change edge connector. |
|
|
|
G |
31171 |
Token ring card failures when in the same node with more than four |
|
|
SDB2 boards. |
|
|
|
H |
31707 |
SDB2 cards were failing power-on diagnostics with a |
|
|
"Spurious interrupt" error. |
|
|
|
J |
31911 |
Elan board crashes when in the same node with SDB2 with high traffic. |
|
|
|
K |
31732C |
Incorporate revised artwork to eliminate rework. Revised artwork will |
|
|
replace both G06 and G08. |
|
|
|
L |
32072 |
SDB2 cards were failing during Memory read/write. Bad IBC_CLK. |
|
|
|
M |
35198 |
Convert 72178G10 back to 72178F08 for cost purposes. |