Kodak T-Max 400 (D-76) Development Chart

Testing Conditions:

Hasselblad 2000FC/M + CFi150/4 + A12 magazine
Sekonic L-508 1o Spot meter
Stainless Steel Tank processing, agitate continuously in the 1st minute and every 10 seconds (inverted 10 times) at 60 seconds interval
Kodak D-76 Developer (1:1) at 20oC
Kodak Indicator Stop Bath (1 min)
Kodak Rapid Fixer (10 min)
X-Rite Densitometer 311

 

Observation

The first test was developed according to Kodak's recommended time.  The time is right to the spot for N development but the Zone I density is suggesting an exposure index of 640.

It seems that the speed of TMY response more to development time TMX does.

 

Density

Development N-2 N-1 N N+1 N+2
Exposure Index 320 500 640 640 800
Development Time (min) 8 10 12.5 15 17.5
Dmin+fog 0.13 0.14 0.14 0.15 0.15
Zone Density (above Dmin+fog)
O 0.04 0.05 0.05 0.04 0.03
I 0.11 0.11 0.10 0.12 0.14
II 0.21 0.24 0.28 0.33 0.37
III 0.30 0.39 0.47 0.58 0.69
IV 0.41 0.52 0.63 0.80 0.97
V 0.52 0.64 0.77 1.00 1.23
VI 0.64 0.80 0.95 1.16 1.36
VII 0.79 0.96 1.13 1.32 1.50
VIII 0.94 1.13 1.31 1.51 1.71
IX 1.09 1.31 1.52 1.75 1.97
X 1.24 1.49 1.74 1.97 2.20
XI 1.33 1.64 1.96 2.19 2.42
Contrast (III-VIII) 0.42 0.49 0.56 0.62 0.68
Contrast (I-X) 0.42 0.51 0.61 0.69 0.76

 

Comparison Chart

Back