Conductivity meter |
|
|
![]()
|
|
||||||||||||||
![]()
Fast, simple measurement of the
foremilk sample, using small sample volume,
| Exact values through digital
display, no subjective influence by the milker,
| No additional
chemicals necessary,
| Direct relationship of conductivity value with
outset of infection,
| Direct indication of
mastitis-suspect quarters,
| Memory holds the conductivity
values of one udder (four measurements),
| Simple operation thanks to
automatic calibration,
| No battery replacement necessary, the
Mast O Test V.2 is powered by a lithium battery sufficient to giver 50 000
readings +. | Light: weight: 230 grams | Robust: Casing injection molded - 2 mm
Terluran® (very high impact resistant) | |
| Battery voltage: | 3.6 V |
| Minimum number of tests: | 50 000 |
| Test time: | 8 seconds |
| Temperature compensation ; automatic NTC, range: | 5-45 °C |
| Limit for dirty cell: | > 1 mS/cm |
| Limit for red LED: | > 7 mS/cm |
| Range for yellow LED: | 5.4 … 6.9 mS/cm |
| Limit for green LED: | < 5.3 mS/cm |
| Quarter evaluation: | > 15 % in relation to the smallest value |
| (only values > 2.5 mS/cm are accepted) | |
| Measuring range: | 0 -12 mS/cm |