Table # 4.3
SEWER GG/
|
Descriptive |
Polpulation |
Avg.Daily |
Peak flow |
Storm |
Design |
Design |
Exist. Dia |
Remarks |
|
Category |
Flow |
allowance |
flow |
Dia |
|
|||
|
|
(person) |
m3/d |
m3/d |
m3/d |
m3/d |
(mm) |
(mm) |
|
|
|
||||||||
|
Museum |
400 |
15.14 |
60.56 |
60.56 |
136.26 |
69 |
150 |
satisfactory |
|
Center of |
||||||||
|
Excellence |
40 |
6.06 |
24.23 |
24.23 |
54.54 |
Sum =190.8 m3/d
=0.00221 m3/s
Sewer line FF/:
Table # 4.4
|
Descriptive Category
Chemistry Dept. Primary School Annexy block Ali mardan Hall Qasim hall Khalid Hall New hall
|
Population (Persons)
30
400
416
112
200 112
100 |
Avg.daily Flow (m3/d) 1.14
7.57
62.99
17
30.28 17
15.14 |
Peak Flow (m3/d) 4.542
30.28
252
68
121.12 68
60.56 |
Storm Allowance (m3/d) 4.542
30.28
252
68
121.12 68
60.56 |
Design Flow (m3/d) 10.26
68.13
566.91
153
272.52 153
136.26 |
Design Diu (mm)
183 |
Existing Dia (mm)
150 |
Remarks
Under-sized |
Sum =1360.1 m3/d
=0.01574 m3/s
4.3.1 WET WELL AND PUMP AT DISPOSAL STATION NO. 1:
TABLE 4.5
|
Total Sewage Flow in Wet well
|
Designed Capacity Of wet well
|
Existing Capacity
|
Pump Capacity
|
Designed |
Existing |
||
|
Suction Pipe
|
Delivery Pipe
|
Suction Pipe
|
Delivery Pipe
|
||||
|
0.0367 |
5.507m3
|
20.4 m3 |
0.0283 m3/s
|
225mm |
225mm |
100mm |
100mm |
Comments:
The capacity of wet well existing is all right even it is quite more than the required.
The design capacity of wet well is given by the following formula:
V =Tmin .Q/4
The value of Tmin. is usually greater than 5 minutes, in our design procedure we have taken it 10 minutes.
Total incoming sewage to this disposal station is 0.0367 m3/s but the capacity of pump is 1 cu sec (0.0283 m3/s) so pump is equate but the suction and the delivery pipes are under sized.
Note:
The velocity in the suction pipe ranges from 1-1.5 m/s in the delivery pipe ranges from 2-2.5 m/s. in the design procedure we took 1.25 m/s for suction pipe and 2.25 m/s for delivery pipe.
SEWAGE DISPOSAL STATION #2:
This disposal point is situated near the colony just before the boundary wall of the University. Trunk sewer KK’ designates it as shows in the fig. 5.2
At this point there is no pump used for pumping the sewage. The sewage is being disposed to the near by passing WASA sewer under gravity.
We tabulated the hydraulic calculations for each sewer and saw whether the Sewer are adequate or under sized.
Trunk sewer JK/ :
Table # 4.6 (ON NEXT PAGE)
|
Descriptive Category |
Popula-tion (Persons) |
Avg. daily flow (m3/d) |
Peak flow (m3/d) |
Storm allow-ance (m3/d) |
Design flow (m3/d) |
Design dia (mm) |
Existing Dia (mm) |
Remarks |
|
Liaquat Hall Quaid-e-Azam hall Sir syed hall Iqbal hall Zafar hall Sports-complex Madina Canteen P.D. Office Bachelor Flat (44F-type+44Etype) 6-P type 54 servant quarters 10-R type 8-L type |
202
202
202 202 130 200
100
50 32
704
48 432
80 64 |
30.58
30.58
30.58 30.58 19.682 30.28
15.14
1.893 9.084
199.85
13.63 122.63
22.71 18.17 |
122.33
122.33
122.33 122.33 78.73 121.12
60.56
7.57 36.37
799.4
54.51 490.54
90.84 76.672
|
122.33
122.33
122.33 122.33 78.73 121.12
60.56
7.57 36.37
799.4
54.51 490.54
90.84 76.672
|
275.22
275.22
275.22 275.22 177.14 272.52
136.26
17.04 81.76
1798.65
122.67 1103.67
204.39 163.53
|
357 |
375 |
|