The article by A. Tukker
"Uncertainty in Life-Cycle Impact Assessment of Toxic Releases"
definitely presents a number
of interesting thoughts and realities (Vol. 3, No. 5 pp246 - 258).
However,
a number of points require some clarification and expansion:
1) |
EUSES and similar
models like CalTOX are often used for preliminary screening but are not
limited to
this role. For LCA, these models provide a prediction of the potential
long-term
contribution to risk associated with a continuous or time-averaged unit
release
of a chemical. The tool embodies "state-of-the-art" research efforts,
which
are continually under review. There are obviously variations and
limitations
in terms of applicability associated with the mechanisms represented,
the
type of chemicals that can be readily considered and the use of generic
regional
parameters. However, if needed and justified by additional information,
generic
models can be readily modified to be appropriate for specific cases.
|
2) |
It is suggested in
Section 4.2 of the paper that the residence time or persistence of a
toxic substance in the environment is not treated as a parameter of
interest in its own right in current LCIA approaches. In a steady-state
multimedia model like EUSES, the concentration of a chemical in any
media is linearly proportional to its
residence time in the modeled region. Therefore residence time is
implicitly considered. However, atmospheric and aquatic advection rates
used in the model
can significantly influence this value, thus the concentration in any
media
and hence the calculated equivalency factor. Selection of the region
boundaries
and associated advection rates can therefore significantly influence
the
outcome of a relative comparison in an LCA.
The intrinsic persistence of a chemical,
a measure of its duration in the environment and not just in a given
region, is only addressed if a "unit world" or a global model approach
is used. There is no removal from the system except by degradation
(i.e. a closed system). Intrinsic persistence is now being used in
national and international applications to identify a number of
chemicals of potential concern (e.g. see the support materials for the
draft US EPA Persistent Bioaccumulative Toxics (PBTs)
Chemical List at www.epa.gov/wastemin/). As A. Tukker points out, the
intrinsic
nature of a chemical is not typically addressed in LCA.
Regulatory actives
differ from LCA by identifying chemicals of potential concern,
irrespective of the levels of release - the "precautionary principle".
Unlike LCA, a highly persistent chemical of concern released in even
very small quantities is considered to
be a bigger problem than a large release of a low concern chemical.
There are a number of reasons for this, including the potential ability
of these chemical to effect impacts at remote locations with sensitive
ecosystems. To mirror this regulatory approach, LCA would need to adopt
an ordinal classification step to distinguish low from high concern
chemicals prior to the use of current quantitative characterization
practices.
|
3) |
The common use of
deterministic values (one set of values) in LCA is a concern, although
this may be intentional in Tukker's paper. Environmental parameters,
particularly degradation rates, are extremely variable. It is often not
possible to state that a given value is incorrect, particularly when
considering a variety of climatic zones, seasonal
variations, etc. The three risk sets based on different data of A.
Tukker
may all therefore be realistic values. What is unknown is the
likelihood of
each prediction. For example, which is nearest the median, the 5th
percentile the 95th percentile, etc.
LCA needs to embrace the use of
probabilistic approaches like those presented in CalTox and, hopefully,
in future releases of EUSES. Sensitivity analysis should be used to
identify the important parameters prior to specification of the
associated ranges with greater precision.
The lack of sensitivity analysis has, for example, often led to
misleading
conclusions related to the need of degradation data for all media and
therefore
limited use of multimedia models. In reality, many toxic equivalency
potentials
can be derived using multimedia models given only an aquatic half-life.
The
time to determine this information and focus resources is trivial
compared
to the time required to collect LCI data.
|
Dr. David W. Pennington
|