BOD Calculator (300 mL bottle)-- Scroll down for formulas

If seed was not used, don't enter anything in top row of boxes .
Enter mL of seed per bottle.Enter BOD of seed.Calculated seed correction is:
Enter mL of sample in bottle.Enter initial D.O.Enter final D.O.
Calculated BOD is:Comment

The calculations:

Seed correction = Seed BOD x mL seed per bottle / 300

BOD = (initial D.O. - final D.O. -seed correction) x 300/mL sample in bottle

If < 2 mg/L D.O. consumed, TOO WEAK.
If < 1 mg/L D.O. remains, TOO STRONG.
Otherwise, BOD is valid.